English
Language : 

HB04UC Datasheet, PDF (2/4 Pages) Murata Power Solutions Inc. – 4.0W Unregulated High Isolation DC/DC Converter
HB04UC
4.0W Unregulated High Isolation DC/DC Converter
ELECTRICAL SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise noted.
MODEL
NOMINAL
INPUT
VOLTAGE
(VDC)
RATED
OUTPUT
VOLTAGE
(VDC)
RATED
OUTPUT
CURRENT
(mA)
INPUT CURRENT
NO LOAD
(mA)
RATED LOAD
(mA)
HB04U05S05QC
5
HB04U05S12QC
5
HB04U05S15QC
5
HB04U12S05QC
12
HB04U12S12QC
12
HB04U12S15QC
12
HB04U15S05QC
15
HB04U15S12QC
15
HB04U15S15QC
15
HB04U05D05QC
5
HB04U05D12QC
5
HB04U05D15QC
5
HB04U12D05QC
12
HB04U12D12QC
12
HB04U12D15QC
12
HB04U15D05QC
15
HB04U15D12QC
15
HB04U15D15QC
15
5
800
12
333
15
267
5
800
12
333
15
267
5
800
12
333
15
267
±5
±400
±12
±167
±15
±134
±5
±400
±12
±167
±15
±134
±5
±400
±12
±167
±15
±134
60
1000
60
1000
60
1000
25
380
25
380
25
380
20
310
20
310
20
310
60
944
60
944
60
944
25
375
25
375
25
375
20
300
20
300
20
300
Note: Other input to output voltage options may be available. Please consult factory.
Models with strikethrough have been discontinued.
COMMON SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise noted.
PARAMETER
INPUT
Voltage Range
Reflected Ripple Current
CONDITIONS
MIN
TYP
4.5
5
10.8
12
13.5
15
351
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
60 Hz, 10 Seconds
VISO= 240VAC, 60Hz
3000
8000
10
10
1.2
OUTPUT
Rated Power
Voltage Setpoint Accuracy
Temperature Coefficient
Ripple & Noise
BW = 10Hz to 2MHz
Line Regulation
Load Regulation
BW = DC to 10MHz
High Line to Low Line
See performance curves
4
±3
±0.02
100
20
±1.5
GENERAL
Switching Frequency
Package Weight
MTTF per MIL-HDBK-217, Rev. E
Ground Benign
Circuit Stress Method
TA = +25°C
100
22
200,000
TEMPERATURE
Specification
-25
Operation
-40
Storage
-40
1. Reflected ripple current is measured at 50% load with a 33uF capacitor across the input of the UUT.
EFFICIENCY
(%)
80
80
80
87
87
87
87
87
87
85
85
85
88
88
88
88
88
88
MAX
5.5
13.2
16.5
2
±5
+70
+85
+110
UNITS
VDC
mAp-p
VDC
Vpk
GΩ
pF
μArms
W
%
%/°C
mVp-p
mVrms
%/% Vin
kHz
g
Hr
°C
°C
°C
www.murata-ps.com
Technical enquiries - email: sales@murata-ps.com, tel: +1 508 339 3000
HB04UC.A01 Page 2 of 3