English
Language : 

EUS20-120 Datasheet, PDF (2/7 Pages) Murata Power Solutions Inc. – Bus Converter
Murata Power Solutions
Table 1
Protection Characteristics
Output Over-Current Shutdown
Over Temperature Shutdown (5)
Over Temperature Restart Hysteresis
Notes & Conditions 0
Non-Latching
Re-start rate
Non-Latching
Table 2
General Specifications
Isolation Voltage
Isolation Resistance
Storage Temperature Range
Operating Temperature Range
Thermal Measurement Location Temperature (7)
Material Flammability
MTBF
Dimension
Weight
Notes & Conditions 0
Input to Output
Input to Output
Non-condensing
Ambient (7)
See mechanical drawing for location
UL 94V-0
Calculated (Bellcore TR-332)
Demonstrated
2.28”L x 0.9”W x 0.48”H (max)
(57.9L x 22.9W x 12.19H mm max)
Table 3
Standards Compliance
UL/CSA 60950
EN60950
Notes & Conditions (6)
Basic Insulation
Certified by TUV
BUS CONVERTER
EUS20-120 Model
Min
Typ. Max Units
24
25
27
A
75
msec
125
130 °C
10
°C
Min
2250
10
-40
-40
Typ.
2.7
2
Max
125
100
120
Units
Vdc
Mohm
°C
°C
°C
x106 Hrs
x106 Hrs
30
grams
Notes:
Vin = 48Vdc, Ta = 25 °C, Airflow = 200 LFM for all data unless otherwise noted.
Output ripple voltage and noise is specified when measured with a 10uF tantalum and a 1uF ceramic capacitor at the converter output pins.
Transient response is specified without a capacitor at the output of the converter.
Product operates with an external capacitance significantly greater than specified. However, for values higher than 2000uF please contact
C&D representative.
Thermal shutdown is monitored at the Thermal Measurement Location (TML). See ‘Mechanical Information’ on page 3 for TML location.
See ‘Safety Considerations’ shown on last page.
De-rating curves are conducted in a controlled environment. End application testing is required to ensure the Thermal Measurement
Location temperature is below the maximum specified.
Recommended airflow direction is from pin 1 to pin 3, or 3 to 1 (transverse airflow).
Current share accuracy is optimized when the source and load impedance presented to each converter is equal.
Input Reflected Ripple is specified when measured with a 12uH source inductance.
EUS20-120-6200921520.B01 18/04/08