RBC-12-D48 Datasheet, PDF (1/10 Pages) Murata Power Solutions Inc. – Quarter Brick, Regulated Bus Converters | |||
|
www.murata-ps.com
Output (V)
12
RBC-12/17-D48 Series
Quarter Brick, Regulated Bus Converters
Current (A)
17
Nominal Input (V)
48
Typical unit
FEATURES
ÂUp to 210 Watts total output power
ÂUp to 93% ultra-high efï¬ciency @ full load
Â48V Input ( up to 36-75V range)
Â12V/17A Output for Regulated Intermediate Bus
Architectures (RIBA) with POL converters
ÂSynchronous-rectiï¬er topology
Â225kHz ï¬xed switching frequency
ÂFully isolated, 2250Vdc (BASIC)
Â2.3" x 1.45" x 0.42" quarter brick
ÂStable no-load condition
ÂThermal shutdown
ÂFully I/O protected
ÂCertiï¬ed to UL/IEC/EN 60950-1 and CSA C22.2
No.60950-1-07, 2nd edition
Optimized for distributed power Regulated Intermediate Bus Archi-
tectures (RIBA), the RBC DC/DC bus converter series offer regulated
outputs (±1.5%) in an industry-standard quarter brick open frame
package.
PRODUCT OVERVIEW
The present trend in distributed power architec-
tures (DPA) requires both high efï¬ciency and some
regulation of the output voltage to reduce the risk
of under voltage dropout. Earlier unregulated bus
converters were simply ratiometric âDC transform-
ers.â The fully isolated (2250Vdc) RBC series accept
a wide range 36 to 75 Volt DC input (48V nominal)
and convert it to an output of 12Vdc. This output
then drives point-of-load (PoL) converters such as
our Okami, LSN, LEN, LSM or LQN series which
feature precise load regulation. Applications include
48V-powered datacom and telecom installations,
base stations, cellular telephone repeaters and
embedded systems. Low overall height of 0.42"
(10.7 mm) ï¬ts tight card cages.
The RBCâs synchronous-rectiï¬er topology and ï¬xed
frequency operation means excellent efï¬ciencies.
âNo fanâ or zero airï¬ow applications may use the
optional base plate for cold surface mounting or
natural-convection heatsinks.
A wealth of electronic protection features include
input undervoltage (UV) lockout, output current limit,
short circuit hiccup, overtemperature shutdown and
output overvoltage. Available options include posi-
tive or negative logic remote On/Off control and the
baseplate. Assembled using ISO-certiï¬ed automated
surface-mount techniques, the RBC series includes
all UL and IEC emissions, safety and ï¬ammability
certiï¬cations.
+VIN
(1)
âVIN
(3)
GATE
DRIVE
+VOUT
(8)
âVOUT
(4)
REMOTE
ON/OFF
(2)
SWITCHING
CONTROLLER
HICCUP
OV, UV, OT
SHUTDOWN
CURRENT
SENSE
Figure 1. Simpliï¬ed Block Diagram
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
VOLTAGE
SENSE
Typical topology is shown.
MDC_RBC-12/17-D48.B02 Page 1 of 10
|
▷ |