English
Language : 

OKY-T10 Datasheet, PDF (1/3 Pages) Murata Power Solutions Inc. – Programmable DOSA-SMT 10/16-Amp DC/DC Converters
This data sheet contains core information only. Please click here for the full data sheet.
www.murata-ps.com
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
Typical unit
FEATURES
„ Wide 2.4-5.5 VDC input range
„ Non-isolated output adjustable from 0.7525 to
3.63 Volts up to 16 Amps
„ DOSA-compatible SMT package
„ Drives 1000 μF ceramic capacitive loads
„ Optional sequence/tracking operation
„ Outstanding thermal performance and derating
„ Short circuit protection
„ On/Off control
„ High efficiency with no heatsink
„ Over temperature protection
„ Designed to meet UL/EN/IEC 60950-1 safety
approvals.
PRODUCT OVERVIEW
The OKY-T/10 and -T/16 series are SMT non-
isolated Point-of-Load (POL) DC/DC power convert-
ers for embedded applications. The module is fully
compatible with Distributed-power Open Standards
Alliance (DOSA) industry-standard specifications
(www.dosapower.com). Applications include pow-
ering CPU’s, datacom/telecom systems, program-
mable logic and mixed voltage systems.
The wide input range is 2.4 to 5.5 Volts DC. Two
maximum output currents are offered, 10 Amps
(T/10 models) or 16 Amps (T/16 models). Based
on fixed-frequency synchronous buck converter
switching topology, the high power conversion
efficient Point of Load (POL) module features pro-
grammable output voltage and On/Off control. An
optional Sequence/Tracking input allows controlled
ramp-up and ramp-down outputs. The Sense input
provides remote sense. These converters also
include under voltage lock out (UVLO), output short
circuit protection, over-current and over tempera-
ture protections.
These units are designed to meet all standard
UL/EN/IEC 60950-1 safety and FCC EMI/RFI
emissions certifications and RoHS-6 hazardous
substance compliance.
Contents of full data sheet
Page
Description, Connection Diagram, Photograph
1
Ordering Guide, Model Numbering
2
Mechanical Specifications, Input/Output Pinout
3
Detailed Electrical Specifications
4
Output Voltage Adjustment, Soldering Guidelines
5
Application Notes
6
Performance Data and Oscillograms – OKY2-T/16-W5
9
Tape and Reel Information
16
Simplified Block Diagram
+Vin
+Vout
F1
On/Off
Control
External
DC
Power
Source
Open = On
Closed = Off
(Positive
On/Off)
Controller
t4XJUDIJOH
t'JMUFST
t$VSSFOU4FOTF
Reference and
Error Amplifier
Sense
Trim
Common
Sequence/Tracking (OKY2 only)
Ḥ
Figure 1. OKY-T/10, -T/16
Common
Note: Murata Power Solutions strongly recommends an external input fuse, F1.
See specifications.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
email: sales@murata-ps.com
19 Oct 2009 MDC_OKY_T10T16.W5.A01_short Page 1 of 3