OKL-T3-W12_10 Datasheet, PDF (1/15 Pages) Murata Power Solutions Inc. – Programmable Output 3-Amp iLGA SMT PoLs | |||
|
www.murata-ps.com
OKL-T/3-W12 Series
Programmable Output 3-Amp iLGA SMT PoLs
Typical unit
PRODUCT OVERVIEW
The OKL-T/3-W12 series are miniature non-iso-
lated Point-of-Load (PoL) DC/DC power converters
for embedded applications. Featuring inspectable
Land Grid Array (iLGA) format, the OKL-T/3-W12
measures only 0.48 x 0.48 x 0.244 inches max.
(12.2 x 12.2 x 6.2 mm max.).
The wide input range is 4.5 to 14 Volts DC.
The maximum output current is 3 Amps. Based
on ï¬xed-frequency synchronous buck converter
switching topology, the high power conversion
efï¬cient Point of Load (PoL) module features
programmable output voltage and On/Off control.
These converters also include under voltage lock
out (UVLO), output short circuit protection, and
over-current protections.
An optional sequence/tracking feature on
OKL2-T/3-W12 models allows power sequencing
of PoLâs. These units meet all standard UL/EN/IEC
60950-1 safety certiï¬cations (2nd Edition) and RoHS-6
hazardous substance compliance.
FEATURES
â iLGA inspectable Land Grid Array
â 4.5-14Vdc input voltage range
â Programmable output voltage from 0.591-5.5Vdc
â Drives up to 200 μF ceramic capacitive loads
â High power conversion efï¬ciency at 93%
â Outstanding thermal derating performance
â Short circuit and over current protection
â On/Off control and Power Good signal
â Optional Sequence/Tracking operation
(OKL2-T/3-W12 models)
â Meets UL/EN/IEC 60950-1 safety, 2nd Edition
â RoHS-6 hazardous substance compliance
Contents
Page
Description, Connection Diagram, Photograph
1
Ordering Guide, Product Label
2
Mechanical Speciï¬cations, Input/Output Pinout
3
Detailed Electrical Speciï¬cations
4
Output Voltage Adjustment, Application Notes
5
Performance Data and Oscillograms
8
Tape and Reel Information
15
Connection Diagram
+Vin
F1
On/Off
Control
External
DC
Power
Source
Open = On
Closed = Off
(Positive
On/Off)
Controller
t4XJUDIJOH
t'JMUFST
t$VSSFOU4FOTF
Reference and
Error Ampliï¬er
Common
Sequence/Tracking
(OKL2 Models)
Ḥ
Power Good
Figure 1. OKL-T/3-W12
Note: Murata Power Solutions strongly recommends an external input fuse, F1.
See speciï¬cations.
For full details go to
www.murata-ps.com/rohs
+Vout
Sense
Trim
Common
www.murata-ps.com
email: sales@murata-ps.com