OKL-T/3-W12 Series
Programmable Output 3-Amp iLGA SMT PoLs
Typical unit
PRODUCT OVERVIEW
The OKL-T/3 series are miniature non-isolated
Point-of-Load (PoL) DC/DC power converters for
embedded applications. Featuring iLGA inspectable
Land Grid Array (LGA) format, the OKL measures
only 0.48 x 0.48 x 0.25 inches (12.2 x 12.2 x 6.35
mm).
The wide input range is 4.5 to 14 Volts DC. The
maximum output current is 3 Amps (T/3 models).
Based on fixed-frequency synchronous buck con-
verter switching topology, the high power conver-
sion efficient Point of Load (PoL) module features
programmable output voltage and On/Off control.
These converters also include under voltage lock
out (UVLO), output short circuit protection, over-
current and over temperature protections.
An optional sequence/tracking feature on OKL2
models allows power sequencing of PoL’s. These
units are designed to meet all standard UL/EN/IEC
60950-1 safety certifications and RoHS-6 hazard-
ous substance compliance.
FEATURES
■ iLGA inspectable Land Grid Array
■ 4.5-14Vdc input voltage range
■ Programmable output voltage from 0.591-5.5Vdc
■ Drives up to 200 μF ceramic capacitive loads
■ High power conversion efficiency at 93%
■ Outstanding thermal derating performance
■ Over temperature and over current protection
■ On/Off control and Power Good signal
■ Optional Sequence/Tracking operation (OKL2
models)
■ Designed to meet UL/EN/IEC 60950-1 safety
(pending)
■ RoHS-6 hazardous substance compliance
Contents of full data sheet
Page
Description, Connection Diagram, Photograph
1
Ordering Guide, Model Numbering, Product Label
2
Mechanical Specifications, Input/Output Pinout
3
Detailed Electrical Specifications
4
Output Voltage Adjustment, Application Notes
5
Soldering Guidelines
7
Performance Data and Oscillograms
8
Tape and Reel Information
15
Connection Diagram
+Vin
F1
On/Off
Control
External
DC
Power
Source
Open = On
Closed = Off
(Positive
On/Off)
Controller
t4XJUDIJOH
t'JMUFST
t$VSSFOU4FOTF
Reference and
Error Amplifier
Common
Sequence/Tracking
(OKL2 Models)
Ḥ
Power Good out
Figure 1. OKL-T/3
Note: Murata Power Solutions strongly recommends an external input fuse, F1.
See specifications.
For full details go to
www.murata-ps.com/rohs
+Vout
Sense
Trim
Common
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000