English
Language : 

OKL-T Datasheet, PDF (1/17 Pages) Murata Power Solutions Inc. – Programmable Output 3-Amp iLGA SMT PoLs
www.murata-ps.com
OKL-T/3-W5 Series
Programmable Output 3-Amp iLGA SMT PoLs
Typical unit
FEATURES
PRODUCT OVERVIEW
■ iLGA inspectable Land Grid Array
■ 2.4-5.5Vdc input voltage range
■ Programmable output voltage from 0.6-3.63Vdc
■ Drives 200 μF ceramic capacitive loads
■ High power conversion efficiency at 95.3%
■ Outstanding thermal derating performance
■ Over temperature and over current protection
■ On/Off control
■ Certified to UL/EN/IEC 60950-1 safety, 2nd Edition
■ RoHS-6 hazardous substance compliance
■ Sequence/Tracking operation (optional)
The OKL-T/3-W5 series are miniature non-
isolated Point-of-Load (PoL) DC/DC power convert-
ers for embedded applications. The tiny form factor
is configured on a Land Grid Array (LGA) assembly
measuring only 0.48 x 0.48 x 0.244 inches max.
(12.2 x 12.2 x 6.2 mm max.).
The wide input range is 2.4 to 5.5 Volts DC.
The maximum output current is 3 Amps. Based
on fixed-frequency synchronous buck converter
switching topology, the high power conversion
efficient Point of Load (PoL) module features
programmable output voltage and On/Off control.
These converters also include under voltage lock
out (UVLO), output short circuit protection, over-
current and over temperature protections.
An optional sequence/tracking feature allows
power sequencing of PoL’s. These units are certi-
fied to all standard UL/EN/IEC 60950-1 safety
certifications (2nd Edition) and RoHS-6 hazardous
substance compliance.
Connection Diagram
+Vin
F1
On/Off
Control
External
DC
Power
Source
Open = On
Closed = Off
(Positive
On/Off)
Controller
t4XJUDIJOH
t'JMUFST
t$VSSFOU4FOTF
Reference and
Error Amplifier
Common
Sequence/Tracking
(OKL2 models)
Power Good out
Figure 1. OKL-T/3-W5
Note: Murata Power Solutions strongly recommends an external input fuse, F1.
See specifications.
+Vout
Sense
Trim
Common
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
MDC_OKL-T/3-W5 Series.C02 Page 1 of 17