English
Language : 

OKDL-T Datasheet, PDF (1/31 Pages) Murata Power Solutions Inc. – 12A Digital PoL DC-DC Converter Series
www.murata-ps.com
OKDL-T/12-W12-xxx-C
12A Digital PoL DC-DC Converter Series
Typical unit
FEATURES
Small package: 12.2 x 12.2 x 8.0 mm (0.48 x 0.48 x 0.315 in)
0.6 V - 5 V output voltage range
High efficiency, typ. 95.4% at 12Vin, 5Vout and 50% load
Configuration Control and Monitoring via PMBus™
Adaptive compensation of PWM control loop & fast loop
transient response
Synchonization input & phase spreading/interleaving
Voltage Tracking & Voltage margining
MTBF 24 Mh
For narrow board pitch applications (15 mm/0.6 in)
Pre-bias start-up & shut down
Monotonic & Soft start Power up
Input under voltage shutdown; OTP, output OVP, OCP
Remote control & Power Good
Differential sense pins
Voltage setting via pin-strap or PMBus™
Advanced Configurable via Graphical User Interface
ISO 9001/14001 certified supplier
Highly automated manufacturing ensures quality
PRODUCT OVERVIEW
The OKDL-T/12-W12 is a high efficiency,
digital point-of-Load (PoL) DC-DC power
converter capable of delivering 12A/60W.
Designed for a minimal footprint, the high
power-density LGA module measures
just 12.2 x 12.2 x 8.0 mm (0.48 x 0.48 x
0.315 in).
PMBus™ compatibility allows monitor-
ing and confi guration of critical system-
level performance requirements.
Applications
Distributed power architectures
Intermediate bus voltage applications
Servers and storage applications
Network equipment
Apart from standard PoL performance
and safety features like OVP, OCP, OTP,
and UVLO, these digital converters have
advanced features: Adaptive compen-
sation of PWM control loop, fast loop
transient response, synchronization,
and phase spreading. These converters
are ideal for use in telecommunica-
tions, networking, and distributed power
applications.
PART NUMBER STRUCTURE
OKD L - T / 12 - W12 - xxx - C
Digital Non-isolated PoL
LGA Package
RoHS Hazardous
Substance Compliance
C = RoHS-6 (does not claim EU RoHS exemption
7b – lead in solder)
Trimmable Output
Voltage Range
0.6 - 5Vdc
Maximum Rated Output
Current in Amps
Software Configuration Digits
(001 is positive turn-on logic)
(002 is negative turn-on logic)*
Input Voltage Range
4.5-14Vdc
*Special quantity order is required;
contact Murata Power Solutions for
MOQ and lead times.
PM
www.murata-ps.com/support
MDC_OKDL-T/12-W12-xxx-C.A02 Page 1 of 31