English
Language : 

NCS6 Datasheet, PDF (1/6 Pages) Murata Power Solutions Inc. – Isolated 6W 4:1 Input Single Output DC/DC Converters
www.murata-ps.com
NCS6 Series
Isolated 6W 4:1 Input Single Output DC/DC Converters
FEATURES
RoHS compliant
4:1 Wide range voltage input
Operating temperature range –40°C to
85°C
Typical load regulation from 0.06%
1.5kVDC Isolation
Typical efficiency to 87%
12V & 48V Nominal input
Power density 0.94W/cm3
UL 94V-0 Package materials
No electrolytic capacitors
Low noise
Under voltage lock out
Current fold back
PRODUCT OVERVIEW
The NCS6 series of DC/DC converters offers
single output voltages from input voltage ranges
of 9-36V and 18-75V. The NCS6 is housed in
an industry standard package with a standard
pinout. The NCS6 is packaged in a metal case for
improved EMI shielding and is also encapsulated
for superior thermal performance.
Applications include telecommunications, battery
powered systems, process control and distributed
power systems.
Ḥ
For full details go to
www.murata-ps.com/rohs
SELECTION GUIDE
Input
Voltage
Order Code
Nom.
V
NCS6S1203C
12
NCS6S1205C
12
NCS6S1212C
12
NCS6S1215C
12
NCS6S4803C
48
NCS6S4805C
48
NCS6S4812C
48
NCS6S4815C
48
Output
Voltage
V
3.3
5
12
15
3.3
5
12
15
Output
Current
100%
Load
A
1.52
1.2
0.5
0.4
1.52
1.2
0.5
0.4
Input Current
Current
0% 100%
Load Load
mA mA
10 550
7
610
10 580
12 580
10 150
6
160
7
150
7
150
Ripple &
Noise
(Typ.)
mV p-p
30
30
30
30
40
30
30
30
Efficiency
Min. Typ.
%
%
75
78
79
82
84
86
85
87
73
76
78
80
82
84
83
84
MTTF1
Hrs
662,073
521,975
435,567
437,582
483,460
441,850
408,555
416,319
INPUT CHARACTERISTICS
Parameter
Conditions
Voltage range
All NCS6S12 types
All NCS6S48 types
Turn on threshold NCS6S12
Under voltage lock out
Turn off threshold NCS6S12
Turn on threshold NCS6S48
Turn off threshold NCS6S48
Reflected ripple current
All NCS6S12 types
All NCS6S48 types
Min. Typ. Max. Units
9
12
36
V
18
48
75
8.5
7.5
V
16.7
15.8
12
mA p-p
9
OUTPUT CHARACTERISTICS
Parameter
Conditions
Rated power
5V, 12V & 15V output types
3.3V output types
Voltage set point accuracy
Line regulation
Low line to high line
Load Regulation
10% total load to
100% total load
NCS6Sxx03C
NCS6Sxx05C
NCS6Sxx12C, NCS6Sxx15C
3.3V & 5V output types
Start-up Time
12V output types
15V output types
Min. Typ. Max. Units
6
W
5
±2
%
0.002 0.2
%
0.5
0.6
0.3
0.5
%
0.06 0.2
2.5
4.6
mS
5.5
ISOLATION CHARACTERISTICS
Parameter
Conditions
Isolation test voltage
Flash tested for 1 seconds
Resistance
Viso = 1kVDC
Capacitance
Min. Typ. Max. Units
1500
VDC
1
GΩ
225
pF
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection (for SELV input voltages)
Internal power dissipation
Lead temperature 1.0mm from case for 10 seconds
(to JEDEC JESD22-B106 ISS C)
Minimum output load for specification (see application notes)
Input voltage, NCS6 12V input types
Input voltage, NCS6 48V input types
Continuous
2.1W
260°C
10% of rated load
40V
80V
1 Calculated using MIL-HDBK-217F FN2, parts stress method with nominal input voltage at full load.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
www.murata-ps.com
Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232
2009-09-21 KDC_NCS6C.B01 Page 1 of 6