MVAD160-48 Datasheet, PDF (1/6 Pages) Murata Power Solutions Inc. – 160W 2 X 4 AC-DC Power Supply Converter | |||
|
www.murata-ps.com
FEATURES
ï®ï 110W Wide Operating Temperature range
AC-DC Power Supply
ï®ï IT (2nd Ed.) and Medical (3rd Ed. MOPP) safety
approved, excluding conduction cooling condi-
tion
ï®ï 2" x 4" standard footprint
ï®ï High efï¬ciency up to 93%
ï®ï Remote sense
ï®ï Remote On/Off (for V1, Negative logic)
ï®ï Universal AC input
ï®ï Low proï¬le - 1U package
ï®ï Convection, conduction, and forced-air cooled
operation
ï®ï Complies with 5000m altitude (at class I IT
equipment)
ï®ï RoHS compliant
ï®ï Less than 0.3W input power at no load remote
âoffâ
ï®ï Complies with ErP/Energy star requirement
(average efï¬ciency > 87%)
Available now at
http://power.murata.com/acdc3d
hptotwp:e/r/.pmouwreart.am.cuormata.com
MVAD160 Series
160W 2" X 4" AC-DC Power Supply Converter
DESCRIPTION
The MVAD160 series switching power supplies utilize advanced component and circuit technologies
to deliver high efï¬ciency. Designed for Medical, Telecom, and Industrial applications to satisfy 1U
height design considerations, the MVAD160 Series measures only 2.0" x 4.0" x 1.5". All models offer
universal AC input and compliance to worldwide safety and EMC standards.
ORDERING GUIDE
Model Number
Natural Convection Conduction Cooling Forced Air Cooling Main
Cooling (@ta = 50°C) (@ta = 85°C) (@350LFM /ta=50°C) Output (V1)
Aux Output (V2)
MVAD160-125
12V
MVAD160-245
24V
5V
MVAD160-485
MVAD160-12
110W
110W
160W
48V
12V
no aux output
MVAD160-24
24V no remote sense
MVAD160-48
48V
no V1 remote
INPUT CHARACTERISTICS
Parameter
Input Voltage Operating Range
Input Frequency
Turn-on Input Voltage
Turn-off Input Voltage
Input Current
Inrush Current
Conditions
Min. Typ. Max. Units
Single phase
851 120/230 264
Vac
DC2
200
300 Vdc
47 50/60 63
Hz
Input rising at full load
Input falling at full load
84
84
Vac
90Vac input, full load
2.1
A
At 264Vac, at 25°C cold start
100
Apk
OUTPUT CHARACTERISTICS
Model Number
Main Output
Voltage (V1)
MVAD160-12x
12V
MVAD160-24x
24V
MVAD160-48x
48V
Model Number
Aux Output
Voltage (V2)
MVAD0160-xx5
5V
Load Current
0 to 13.34A
0 to 6.67A
0 to 3.34A
Load Current
0 to 0.1A
Load Capacitance
0 to 1500μF
0 to 680μF
0 to 330μF
Load Capacitance
0 to 220pF
Line, Load, Cross
Regulation
± 2%
Line, Load,
Cross Regulation
± 5%
Typical Efï¬ciency
@230Vac full load
92%
93%
Main Output Characteristics (all models)
Parameter
Transient Response
Conditions
Min. Max. Units
50% load step, min.5% load, 1A/μsec slew rate
± 5 %V1
Settling Time to 1% of Nominal
Turn On Delay
Output Voltage Rise
Setpoint Accuracy
50% load step, min.5% load, 1A/μsec slew rate
After application of input power
Monotonic,5 0 to 100% load
115Vac, 110W load, 25°C
2
1.5
200
± 0.5
msec
sec
msec
%V1
Output Holdup
100% load
10
msec
Temperature Coefï¬cient
Ripple Voltage & Noise3
min. 5% load
0.02 %/°C
1
%V1
Compensates for up to total 400mV of positive
Remote Sense
and negative lead drops with remote sense
400
mV
connected.
1 Refer to power derating curve vs. input voltage. Input test condition on safety approval : 100-240Vac ±10%.
2 Applicable for IT Equipment only.
3 Ripple and noise are measured with 0.1 μF of ceramic capacitance and 47 μF of electrolytic capacitance on each
of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short
coaxial cable with 50Ω scope termination is used.
4 Unless otherwise speciï¬ed all readings are taken at 115Vac input and 25°C ambient temperature.
5 This power supply may exhibit up to 5% turn on overshoot.
CB
Test Certiï¬cate
and Test Report
MVAD160.A05 Page 1 of 6
|
▷ |