English
Language : 

MVAD065-05 Datasheet, PDF (1/7 Pages) Murata Power Solutions Inc. – 65W 2 x 4 AC-DC Power Supply Converter
www.murata-ps.com
FEATURES
„„ITE (2nd Ed.) and Medical (3rd ed.) MOPP
safety approved
„„55-65W compact high density
„„2" x 4" standard footprint
„„High efficiency up to 90%
„„Remote Sense
„„Universal AC input
„„Low profile - 1U package
„„Convection-cooled operation up to 65W
„„Complies with 5000m altitude
„„RoHS compliant
„„Input power < 74W
„„UL Class I and II approved
„„Less than 0.3W no load input power
„„Complies with ErP/Energy Star requirement
excluding 5V output
Available now at
http://power.murata.com/acdc3d
FwowrwFfou.mrllfuudrllaedttaea-tpailsisls.cggooomt/toroohs
www.murata-ps.com/rohs
power.murata.com
MVAD065 Series
65W 2" x 4" AC-DC Power Supply Converter
DESCRIPTION
The MVAD065 series switching power supplies utilize advanced component and circuit technologies
to deliver high efficiency. Designed for Medical, Telecom, and Industrial applications to satisfy 1U
height design considerations, the MVAD065 Series measures only 2.0” x 4.0” x 1.3”. All models offer
universal AC input and compliance to worldwide safety and EMC standards.
ORDERING GUIDE
Model Number
MVAD065-05
MVAD065-12
MVAD065-18
MVAD065-24
MVAD065-48
Natural Convection Cooling
55W
60W
65W
Main Output (V1)
5V
12V
18V
24V
48V
INPUT CHARACTERISTICS
Parameter
Input Voltage Operating Range
Input Frequency
Turn-on Input Voltage
Turn-off Input Voltage
Input Current
Inrush Current
5V
Other
Conditions
Min. Typ. Max. Units
Single phase
90 120/230 264 Vac
DC
120
300 Vdc
47 50/60 63
Hz
Input rising at full load
70
Input falling at full load
70
85
85
Vac
90Vac input, full load
1.4
A
At 264Vac, at 25°C cold start
75
60
Apk
OUTPUT CHARACTERISTICS
Model Number
Main Output
Voltage (V1)
MVAD065-05
5V
MVAD065-12
12V
MVAD065-18
18V
MVAD065-24
24V
MVAD065-48
48V
Load Current
0 to 11A
0 to 5.0A
0 to 3.34A
0 to 2.71A
0 to 1.36A
Load Capacitance
0 to 2200μF
0 to 1000µF
0 to 680μF
0 to 560µF
0 to 330µF
Line, Load, Cross
Regulation
± 2%
± 2%
± 2%
± 2%
± 2%
Typical Efficiency
@230Vac full load
84%
88%
86%
89%
90%
MAIN OUTPUT CHARACTERISTICS
Parameter
Conditions
Min.
Max.
5V Other
Units
Transient Response
50% load step, 1A/µsec slew rate
±5
%
Settling Time to 1% of Nominal
500 200 µsec
Turn On Delay
Output Voltage Rise
After application of input power
Monotonic, 0 to 100% load
1
sec
50
msec
Setpoint Accuracy
120Vac, 40W, 25°C
±1 ±0.5 %
Output Holdup
115Vac, 100% load
10
msec
Temperature Coefficient
Ripple Voltage & Noise1
0.02
%/°C
21
%
Compensates for up to 400mV
Remote Sense3
of lead drop with remote sense
connected. Protected against short
400
mV
circuit and reverse connection.
1. Ripple and noise are measured with 0.1 uF of ceramic capacitance and 47 uF of electrolytic capacitance on each
of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short
coaxial cable with 50ohm scope termination is used.
2. Unless otherwise specified all readings are taken at 120Vac input and 25°C ambient temperature.
3. 0.4V lead drop is compensated in remote sense.
REG.-Nr. C457
CB
Test Certificate
and Test Report
MVAD065.B01  Page 1 of 7