MVAC250-24AFD Datasheet, PDF (1/9 Pages) Murata Power Solutions Inc. – 250W 3 x 5 High Density AC-DC Power Supply Converter | |||
|
www.murata-ps.com
FEATURES
ï®ï IEC60601 Ed.3 medical (2 x MOPP Pri-Sec)
EN60950 ITE safety approved
ï®ï 250W compact high density
ï®ï 3" x 5" standard footprint
ï®ï High efï¬ciency up to 94%
ï®ï Remote sense
ï®ï Remote On/Off, Power OK (MVAC250-xxAFx)
ï®ï Universal AC input with active PFC
ï®ï Less than 1U high â 1.4"
ï®ï Convection cooled operation up to 170W
ï®ï Isolated 12V@1A fan output
ï®ï Isolated 5V@2A standby/auxiliary output with
models MVAC250-xxAFx
ï®ï RoHS compliant
ï®ï Active inrush protection
ï®ï Current sharing option
DESCRIPTION
The MVAC250 series switching power supplies
utilize advanced component and circuit
technologies to deliver high efï¬ciency. Designed
for medical, computing, communications, telecom
and other OEM applications to satisfy 1U height
design considerations, the MVAC250 Series
measures only 3.0" x 5.0" x 1.40". All models
offer universal AC input with active power factor
correction (PFC) and compliance to worldwide
safety and EMC standards.
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
Available now at
www.murata-ps.com/en/3d/acdc.html
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
MVAC250 Series
250W 3" x 5" High Density AC-DC Power Supply Converter
ORDERING GUIDE
Model Number
MVAC250-12F
Natural Convection Cooling
Forced Air Cooling
Main Output Fan Output Aux Output
(V1)
(V2)
(V3)
12V
12V
MVAC250-24F
24V
12V
MVAC250-48F
50V
12V
MVAC250-12AF
MVAC250-12AFD*
170W
250W @ 250LFM
12V
12V
12V
12V
5V
5V
MVAC250-24AFD*
24V
12V
5V
MVAC250-48AFD*
50V
12V
5V
MVAC250-24AFT#
24V
12V
5V
MVAC-COVER
Optional cover kit assembly; see MVAC-COVER datasheet for details
* Refer to page 2 for current sharing model number MVAC250-xxAFD notes.
# CCC Certiï¬cation is not available for these models.
INPUT CHARACTERISTICS
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Operating Range
Single phase
DC
90 115/230 264
Vac
127
300
Vdc
Input Frequency
47 50/60 63
Hz
Turn-on Input Voltage
Turn-off Input Voltage
Input rising
Input falling
80
70
90
80
Vac
Input Current
90Vac input, full load all outputs
3.4
A
No Load Input Power (MVAC250-xxAFD)7 (PS_ON = OFF, 5V_Aux = 0A)
1.5
2.0
W
Inrush Current
At 264Vac, at 25°C cold start
15
Apk
Power Factor
At 230Vac, full load
0.96
OUTPUT CHARACTERISTICS
Model Number
Main Output
Voltage (V1)
MVAC250-12F
12V
MVAC250-24F
MVAC250-24AFT
24V
MVAC250-48F
50V
MVAC250-12AF
12V
MVAC250-12AFD 12V @ 10.4A6
MVAC250-24AFD 24V @ 5.2A6
MVAC250-48AFD 50V @ 2.5A6
Load Current
0.4 to 20.8A
0.2 to 10.4A
0.1 to 5.0A
0 to 20.8A
0 to 20.8A
0 to 10.4A
0 to 5.0A
Maximum Load
Capacitance
0 to 1500μF
0 to 300μF
0 to 82μF
0 to 1500uF
0 to 1500μF
0 to 300μF
0 to 68μF
Line, Load, Cross
Regulation
± 1%
± 1%
± 1%
± 1%
± 1.5%6
± 1.5%6
+3.0% / â1.5%6
Typical Efï¬ciency
@230Vac
93%
93%
94%
93%
93%
93%
94%
Main Output Characteristics (all models)
Parameter
Conditions
Transient Response9
50% load step, 1A/μsec slew rate
Settling Time to 1% of Nominal
Turn On Delay
After application of input power
Output Voltage Rise
Monotonic5
Output Holdup
120Vac/60Hz, full load
Temperature Coefï¬cient
Ripple Voltage & Noise1
Compensates for up to 0.5V of lead drop with
Remote Sense
remote sense connected. Protected against
short circuit and reverse connection.
Typ.
Max. Units
±5
%
500
μsec
3
sec
20
50
msec
0.02 %/°C
1
%
500
mV
Auxiliary Output Characteristics (varies by model)
Auxiliary Output
Aux Output
Voltage8
Load Current
Load Capacitance
Fan (V2) all models
12V
0 to 1A
0 to 220μF
Aux (V3) â MVAC250-xxAFx
5V
0 to 2A
0 to 220μF
Line, Load, Cross Ripple Voltage &
Regulation3
Noise1
± 10%
2%
± 5%
1%
CB
Test Certiï¬cate
and Test Report
MVAC250.B02 Page 1 of 9
|
▷ |