MVAB120-24 Datasheet, PDF (1/7 Pages) Murata Power Solutions Inc. – 120W 2 x 4 AC-DC Power Supply Converter | |||
|
www.murata-ps.com
MVAB120 Series
120W 2" x 4" AC-DC Power Supply Converter
FEATURES
ï®ï ITE (2nd) and Medical 3rd ed. 1MOPP (primary-
secondary) safety approved
ï®ï 120W compact high density
ï®ï 2" x 4" standard footprint
ï®ï High efï¬ciency up to 91%
ï®ï Universal AC input with active PFC
ï®ï Low proï¬le - 1U package
ï®ï Convection-cooled operation up to 75W
ï®ï RoHS compliant
ï®ï UL Class I and II approved (for IT equipment)
DESCRIPTION
The MVAB120 series switching power supplies
utilize advanced component and circuit
technologies to deliver high efï¬ciency. Designed
for Medical, Telecom, and Industrial applications
to satisfy 1U height design considerations, the
MVAB120 Series measures only 2.0" x 4.0"
x 1.35". All models offer universal AC input
with active power factor correction (PFC) and
compliance to worldwide safety and EMC
standards.
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
Available now at
www.murata-ps.com/en/3d/acdc.html
ORDERING GUIDE
Model Number
MVAB120-12
MVAB120-12-01
MVAB120-24
MVAB120-24-01
MVAB120-28
MVAB120-28-01
MVAB120-48
MVAB120-48-01
Medical Approval1 Natural Convection Cooling
No
Yes
No
Yes
No
75W
Yes
No
Yes
Forced Air Cooling
120W @ 250LFM
Main Output
(V1)
12V
24V
28V
48V
INPUT CHARACTERISTICS
Parameter
Input Voltage Operating Range
Input Frequency
Turn-on Input Voltage
Turn-off Input Voltage
Input Current
Inrush Current
Conditions
Single phase
DC1
Input rising at 75W
Input falling at 75W
90Vac input, full load
At 264Vac, at 25°C cold
start
Min. Typ. Max. Units
90 120/230 264
Vac
120
300
Vdc
47 50/60 63
Hz
76
85
Vac
50
1.9
A
75
Apk
OUTPUT CHARACTERISTICS
Model Number
Main Output
Voltage (V1)
MVAB120-12
MVAB120-12-01
12V
MVAB120-24
MVAB120-24-01
24V
MVAB120-28
MVAB120-28-01
28V
MVAB120-48
MVAB120-48-01
48V
Load Current
0 to 10.0A
0 to 5.0A
0 to 4.29A
0 to 2.5A
Load Capacitance
0 to 3300μF
0 to 1000μF
0 to 1000μF
0 to 1000μF
Line, Load, Cross
Regulation
± 2%
± 2%
± 2%
± 2%
Typical Efï¬ciency
@230Vac full load
88%
90%
90%
91%
MAIN OUTPUT CHARACTERISTICS (ALL MODELS)
Parameter
Conditions
Min. Max. Units
Transient Response
50% load step, 1A/μsec slew rate
±5
%
Settling Time to 1% of Nominal
MVAB120-12
MVAB120-24, MVAB120-28, MVAB120-48
750
μsec
500
μsec
Turn On Delay
After application of input power
1
sec
Output Voltage Rise
Monotonic, 0 to 75W
50
msec
Setpoint Accuracy
120Vac, 75W, 25°C
± 0.5
%
Output Holdup
Full load
14
msec
Temperature Coefï¬cient
Ripple Voltage & Noise2
0.02 %/°C
1
%
1 Medical versions not designed for DC input voltage.
2 Ripple and noise are measured with 0.1 μF of ceramic capacitance and 47 μF of electrolytic capacitance on each
of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short
coaxial cable with 50Ω scope termination is used.
3 Unless otherwise speciï¬ed, all readings are taken at 120Vac input and 25°C ambient temperature.
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
CB
Test Certiï¬cate
and Test Report
MVAB120.A13 Page 1 of 7
|
▷ |