English
Language : 

EUS34-096 Datasheet, PDF (1/3 Pages) Murata Power Solutions Inc. – Isolated Bus Converter
EUS34-096
Isolated Bus Converter
FEATURES
RoHS compliant
48 VIN, Isolated, 5:1 fixed conversion ratio
240W output at 38 VIN, 55ºC, 200 LFM
300W output at 48 VIN, 55ºC, 200 LFM
Industry standard 1/8 brick footprint
Remote enable (primary side, positive or
negative)
Over-temperature, over current protections
Direct parallel operation for higher power
DESCRIPTION
The EUS34-096 is a RoHS compliant fixed 5:1
ratio bus converter in an industry standard
eighth brick footprint to support Intermediate
Bus Architecture (IBA) for powering multiple
downstream non-isolated point-of-load (POL)
converters. The output is unregulated and the 5:1
fixed ratio is maintained between the input and
output voltages. It features input voltage range of
38V to 55V, and provides up to 300W @ 48Vin of
power. Typical efficiency of 9.6V module is 96%.
It can be parallel for more power.
INPUT CHARACTERISTICS
Parameter
Input voltage operating range
Input voltage absolute
maximum
Conditions1
Min. Typ. Max. Units
38
48
55
VDC
60
VDC
Input undervoltage lockout
Turn-on threshold
Turn-off threshold
Hysteresis voltage
34
35.5
36
VDC
32
33.5
34
VDC
2
VDC
Input overvoltage lockout
(latching type)
Turn-off threshold
57
58.5 59.5
VDC
Maximum input current
No-load input current
Disabled input current
Steady-state (34 A out)
Enabled state, no load (48 VIN)
Disabled state (48 VIN)
6.7
ADC
100
mA
7
mA
Input reflected ripple current
Measured into the input pin
Input capacitor 47μF type
Nichicon UPM1J470MPH or equivalant
240 mA rms
Inrush current
51
A
Enable - negative logic version
Internal 27.4 KΩ
pulled-up to internal 5.0V
On state range
Off state range
-0.1
0.8
VDC
2.4
15.0
VDC
Resistance from enable pin
to -VIN
With +VIN pin open, or tired to -VIN
TBD
KΩ
OUTPUT CHARACTERISTICS
Parameter
Conditions1
Output voltage set point
VIN = 48V, IO = 0A
Output load regulation
IO = 0 to 34A
Output voltage total regulation
VIN = 38 to 55V, IO = 0 to 34A,
Ta = 55ºC
Output ripple & noise2
20MHz bandwidth
Output current operating range Corresponding to PO = 240W
Efficiency
VIN = 48V, PO = 240W
Turn-on delay
From enable, <0.8V to VO> 10%
for VIN = 38V - 55V
Output voltage rise time3
From 10% to 90%
Start-up inhibit time
Transient response3
Enabled: VIN applied to 90% VOUT
25% step, 1A/μs, ΔVO
Current sharing accuracy
At PO = 240W
Output turn on overshoot
Output turn off undershoot
Maximum output capacitance
Min. Typ. Max. Units
9.40 9.50 9.60 VDC
0.4
V
7.0
11.0 Vdc
50
150 mV p-p
0
34
A
96
%
0.1
10
ms
10
15
ms
150
ms
±3
%VO
3
10
%
0
3
%
0
3
%
3000 μF
1 VIN = 48Vdc, Ta = 25ºC, Airflow = 200 LFM for all data unless otherwise noted.
2 Output Ripple Voltage and noise is specified when measured with a 10uF tantalum and a 1μF ceramic capacitor at the output pins.
3 During output voltage rise time (15 mS Max.), output power shall be limited to 50% constant power.
Transient response is specified with a 960μF capacitor at the output of the converter.
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000