English
Language : 

D2U5T Datasheet, PDF (1/8 Pages) Murata Power Solutions Inc. – AC-DC Three Phase Power Converter
www.murata-ps.com
D2U5T-H3-7000-54-HU4C
AC-DC Three Phase Power Converter
FEATURES
7KW (480VAC), 3.5KW (230VAC) Output Power
High Efficiency; 96% @ 50% FL
54VDC Main Output
3.3V or 5V Standby Output
Dims: 5.1"(W) x 18"(L) x 3.3" (2U)
23.1 watts/cubic inch power density
N+1 redundant (including hot docking)
Droop sharing on Main Output
Over-voltage, over-current, over-temperature
protections
Internal cooling fan
I2C Bus Interface with status indicators
RoHS compliant
Two-year warranty
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
Available now at
www.murata-ps.com/en/3d/acdc.html
Ḥ
For full details go to
www.murata-ps.com/rohs
PRODUCT OVERVIEW
The D2U5T-H3-7000-54-HU4C is a High Efficiency 3500/7000 watt, power factor corrected, three phase power
converter for 230/480VAC lines with a 54VDC main output and a 5V or 3.3V (20W) selectable standby output. The unit is
provided with droop sharing and up to three supplies may be operated in parallel.
The supply is hot pluggable. It recovers from over temperature faults, and has status LEDs on the front panel in addition
to logic and PMBus status signals.
The 2U package and 23.1W/cubic inch power density make them ideal for delivering reliable, efficient power to servers,
workstations, storage systems, broadcast transmitters and many other applications.
ORDERING GUIDE
Model Number
D2U5T-H3-7000-54-HU4C
Power Output
at 480Vac
7000W
Main Output
54V
Standby Output
3.3V or 5V
(selectable)
Airflow
Back to front
INPUT CHARACTERISTICS
Parameter
Input Frequency
Input Voltage Operating Range
Turn-on Voltage (Ramp-up)
Turn-off Voltage (Ramp-down)
Maximum Input Current
Inrush Current
Power Factor, Range 1, 230Vac, 60Hz
Power Factor, Range 2, 480Vac, 60Hz
Conditions
Range 1
Range 2
Range 1
Range 2
Range 1
Range 2
Cold Start
600W
1750W (50% FL)
3500W (100% FL)
600W, 480Vac
3500W (50% FL)
7000W (100% FL)
Min
Typ
Max Units
47 50/60 63
Hz
180
264 Vac
320
525 Vac
176
Vac
280
Vac
150
Vac
260
Vac
15
Arms
30
Apk
0.930
0.990
0.995
0.850
0.990
0.995
OVERALL CHARACTERISTICS
Parameter
Output Power
Efficiency, Range 1
Efficiency, Range 2*
* See graph on page 8.
Conditions
Range 1
Range 2
700W (20%), 230 Vac
1750W (50%), 230 Vac
3500W (100%), 230 Vac
1400W (20%), 480 Vac
3500W (50%), 480 Vac
7000W (100%), 480 Vac
Min
Typ
Max Units
3500
W
7000
89.0
93.5
94.0
%
94.2
96.0
95.5
CB
Test Certificate
and Test Report
www.murata-ps.com/support
D2U5T-H3-7000-54-HU4C.A02 Page 1 of 8