FEATURES
RoHS compliant
1200W (220Vac), 900W (110Vac)
Output power
12V Main output,
3.3V or 5V standby output
1U sized; dimensions 14.0” x 4.0” x 1.6”
13.4 Watts per cubic inch density
N+1 redundancy capable,
including hot-docking
Active current sharing on main output
Over-voltage, over-current,
over-temperature protection
Internal cooling fans
I²C Bus Interface with status indicators
Optional 1U x 19” power-shelf
PRODUCT OVERVIEW
The D1U4-W-1200 is a 1200 Watt, power-factor-corrected (PFC) front-end power supply for hot-
swapping redundant systems. The main output is 12V and standby output of either 5V or 3.3V. Packaged
in 1U low profile, it is designed to deliver reliable bulk power to servers, workstations, storage systems
or any 12V distributed power architecture systems requiring high power density. The highly efficient
electrical and thermal design with internal cooling fans supports reliable operation conditions. The
D1U4-W-1200 is designed to auto-recover from over-current and over-temperature faults. Status
information is provided with front panel LEDs, logic signals and I2C management interface. Three units
can be packaged into an optional 19” 1U power shelf to provide up to 3.6kW of power.
SELECTION GUIDE
Part Number
D1U4-W-1200-12-HC2C
D1U4-W-1200-12-HA2C
D1U4-W-1200-12-HC1C
D1U4-W-1200-12-HA1C
Power Output
High Line AC
1200W
1200W
1200W
1200W
Power Output
Low Line AC
900W
900W
900W
900W
Main Output
12V
12V
12V
12V
Standby
Output
3.3V
5V
3.3V
5V
Airflow
Back to front
Back to front
Front to back
Front to back
INPUT CHARACTERISTICS
Parameter
Input Voltage Operating Range
Input Frequency
Turn-on Input Voltage
Turn-off Input Voltage
Maximum Input Current
Inrush Current
Power Factor
Conditions
Min. Typ. Max. Units
Low Line AC
High Line AC
90
180
140
264
Vac
47 50/60 63
Hz
Ramp up
Ramp down
78.5
70.5
86.5
78
Vac
Low Line AC 90Vac
High Line AC 180Vac
15
10
Arms
Cold start between 0-1msec
100 Apk
Output load >90%
95%
Output load >50%
75%
OUTPUT VOLTAGE CHARACTERISTICS
Output
Voltage
Parameter
Conditions
12V
3.3Vsb
5Vsb
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Output Current
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Operating Range
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Operating Range
Load Capacitance
20MHz Bandwidth
20MHz Bandwidth
20MHz Bandwidth
Min.
11.75
0
3.2
0
4.85
0
Typ.
12.12
3.3
5
Max.
12.48
120
98.3
40000
3.4
33
6
1530
5.15
50
4
1530
Units
Vdc
mV p-p
A
μF
Vdc
mV p-p
A
μF
Vdc
mV p-p
A
μF
1 Ripple and noise are measured with 0.1 uF of ceramic capacitance and 2 x 270 uF of OSCON capacitance on each
of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short coaxial
cable with 50ohm scope termination is used. See Ripple Test Setup diagram.
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries email: toronto@murata-ps.com, tel: +1 (866) 740 1232
D1U4-1200-12-Hx.A03 Page 1 of 5