English
Language : 

CPCI325D-101C Datasheet, PDF (1/4 Pages) Murata Power Solutions Inc. – 325 Watt, 3U x 8HP CompactPCI™
cPCI325D-10xC Series
325 Watt, 3U x 8HP CompactPCI™
SELECTION GUIDE
Model Number
Power
Output Current
5V 3.3V 12V -12V
Modification
CPCI325D-101C
325W
30A 40A 5A 1A Customer PN in FRU
Yes
CPCI325D-10xC
325W
30A 40A 5A 1A Customer defined
Yes
FEATURES
3U x 8HP
36-75 VDC Input range
325 watt continuous output power
Complies with PICMG 2.11 R1.0 with 47
Pin I/O connector
Hot-swap capable
No minimum load
Outputs individually protected against
overloads; automatic recovery
IPMI functionality
Operating temperature 0ºC-50ºC
Full power with 200lfm airflow
DESCRIPTION
The cPCI325D-10xC is a high-reliability, 325 watt
power supply for 3U CompactPCI™ systems.
Developed to support hot-swap, redundant
operation, the cPCI325D-10xC is designed for
compliance with PICMG™ 2.11 R1.0 Power
Interface Specification with 47-pin I/O connec-
tor. With integral IPMI functionality, this unit was
developed with high-availability (HA) telecommu-
nications applications in mind. Current sharing and
interal ORing FETs are included to support these
and other applications requiring reliable, hot-swap
performance and N+1 redundant configuration.
The high power density and complement of global
agency approvals provide for an advanced, high-
efficiency power solution for your CompactPCI™
system requirements.
INPUT CHARACTERISTICS
Parameter
Conditions
Min Typ Max Units
Input operating voltage
Input voltage withstand
36
75
Vdc
34
75
Inrush current
36-72VDC input, full load
<8
APK
Input reverse polarity
A shunt diode across the input clears the input fuse in the event that the input polarity
is reversed.
OUTPUT CHARACTERISTICS
Output Number
Rated Output Voltage (VOUT)
Rated Output Current
(IOUT)
Min Typ Max
Total
Output
Regulation1
V1
V2
V3
V4
Parameter
Temperature Coefficient
Output Ripple & Noise
Output Power
Efficiency
Transient Response
Over-Voltage Protection
Minimum Load
Holdup time
Overload Protection
Remote Sense
Current Share
+5.0Vdc
+3.3Vdc
+12Vdc
-12Vdc
30A
+4/ -2%
40A
0A
5.0A
±4%
1.0A
Conditions
Min Typ Max Units
0.02 %/ºC
20MHz bandwidth V1, V2
20MHz bandwidth V3, V4
50
120 240
mV
p-p
50ºC MAX. temp., 200 Ifm
325
W
48VDC input, full load
80
%
Peak deviation (50-100% & 100-50% step)
±5
%
Settling time (within 1% VOUT NOM)
All outputs
All outputs
500
μs
125 135
%V
nom
0
A
From -54VDC input
4
msec
Outputs are individually protected against overloads and indefinate short circuit with
automatic recovery upon removal of the fault condition. Overload response for outputs
V1-V3 is constant-current mode, with hiccup mode response to a hard short. Overload
response for V4 is linear foldback.
Outputs V1-V3 are capable of compensating >250mV of line drop. Unit automatically
reverts to local sensing in the event that the sense leads are opened for any reason. Unit
is protected against reversed or shorted sense leads.
Active droop current sharing on Outputs V1-V3. Accuracy better than 10% of maximum
rated load. Passive current sharing on output V4. Up to 8 units can be operated in a
parallel array.
NOTES: 1. Totoal regulation includes line, load, & cross regulation.
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232
MPS_cPCI325D-10xC.A01 Page 1 of 4