English
Language : 

CF200-A12C Datasheet, PDF (1/4 Pages) Murata Power Solutions Inc. – 200 Watt High Density AC/DC Power Supply
CF200-A12C
200 Watt High Density AC/DC Power Supply
FEATURES
200W compact high density
Active load current share
Universal AC input with Power Factor
Correction
Ruggedized U-channel construction
RoHS compliant
Includes ORing diode for N+1 parallel
operation
International regulatory approvals
DESCRIPTION
The CF200-A12C switching power supply utilizes
advanced component and circuit technologies to
deliver one of the industry’s smallest 200 Watt
switchers. Built to meet 1U height considerations,
the U-Frame package measures only 3.30 x
5.00 x 1.50”. The CF200-A12C offers universal
AC input (85-265VAC) with active power factor
correction (PFC) and compliance to worldwide
safety and EMC standards.
SELECTION GUIDE
Model Number
CF200-A12C
Power Output
200W
Main Output
12V
Auxilliary Output
5V
INPUT CHARACTERISTICS
Parameter
Input Voltage Operating Range
Input Frequency
Turn-on Input Voltage
Turn-off Input Voltage
Maximum Rated Input Current
Inrush Current
Power Factor
Conditions
Ramp up
Ramp down
100Vac
Cold start at 25°C, 115Vac
Cold start at 25°C, 230Vac
230Vac, full load
115Vac, full load
Min. Typ. Max. Units
85
264 Vac
47
63
Hz
75
Vac
65
2.8 Arms
25
Apk
50
96
%
98
OUTPUT VOLTAGE CHARACTERISTICS
Output
Voltage
Parameter
Conditions
Voltage Set Point Accuracy ±1% tolerance
Line and Load Regulation
12V
Ripple Voltage & Noise1
20MHz Bandwidth
Output Current
Peak Current
Voltage Set Point Accuracy
5Vaux
Line and Load Regulation
Output Current
Ripple Voltage & Noise1
20MHz Bandwidth
Min. Typ. Max. Units
12.2
Vdc
±1
%
150 mV p-p
0
16.6
A
17
5
Vdc
±2
%
0
5
mA
100 mV p-p
OUTPUT CHARACTERISTICS
Parameter
Conditions
Min. Typ. Max. Units
Remote Sense
Compensates for voltage drops of up to 0.5V between the power supply to the
load. Outputs are internally sensed at output connector if remote sense lines are
opened.
Efficiency
Start-up Delay
Rise Time
230Vac, full load
115Vac, full load
Output voltage at 90%
86
%
82
2.0
s
20
ms
Transient Load Response
For load change of 25% to 75%, at
slew rate of 1A/μs, recovery time less
than 2ms
±5
%
Current Sharing Accuracy
Single wire current share in a N+1
parallel redundant configuration with
OR-ng diodes included in the PSU
Hot Swap
Hold-up Time
Overshoot and Undershoot
Available
110Vac, full load
Voltage change at turn-on and turn-off
1 Ripple and noise are measured with 10 μF, in parallel with 0.1 μF ceramic capacitors.
±10
%
16
ms
1
%
www.murata-ps.com
Technical enquiries email: toronto@murata-ps.com, tel: +1 (866) 740 1232
CF200-A12C.A01 Page 1 of 4