English
Language : 

C1U-W-1200-48-TA1C Datasheet, PDF (1/4 Pages) Murata Power Solutions Inc. – AC/DC Front End Power Supply
ht p:/ www.murata-ps.com
FEATURES
RoHS compliant
1200W (110/220Vac) Output power
48V Main output,
3.3V, 5V or 12V standby output
Dimensions: 1.67” x 5.5” x 14.2”
9.2 Watts per cubic inch density
N+1 redundancy capable,
Active current sharing on main output
Over-voltage, over-current,
over-temperature protection
Internal cooling fans
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
C1U-W-1200-48-Tx Series
AC/DC Front End Power Supply
PRODUCT OVERVIEW
The C1U-W-1200 is a 1200 Watt universal AC input, power-factor-corrected (PFC) front-end power
supply for general applications. The main output is 48V and standby output of either 5V, 3.3V, or 12V.
Packaged in U low profile, it is designed to deliver reliable bulk power to servers, workstations, storage
systems or any 48V distributed power architecture systems requiring high power density. The highly
efficient electrical and thermal design with internal cooling fans supports reliable operation conditions.
The C1U-W-1200 is designed to auto-recover from over-temperature faults.
SELECTION GUIDE
Part Number
C1U-W-1200-48-TA1C
C1U-W-1200-48-TC1C
C1U-W-1200-48-TA2C
C1U-W-1200-48-TC2C
C1U-W-1200-48-TB1C
C1U-W-1200-48-TB2C
Power Output
Universal Line
1200W
1200W
1200W
1200W
1200W
1200W
Main Output
48V
48V
48V
48V
48V
48V
Standby
Output
5V
3.3V
5V
3.3V
12V
12V
Airflow
Front to back
Front to back
Back to front
Back to front
Front to back
Back to front
INPUT CHARACTERISTICS
Parameter
Input Voltage Operating Range
Input Frequency
Turn-on Input Voltage
Turn-off Input Voltage
Maximum Input Current
Inrush Current
Power Factor
Conditions
Ramp up
Ramp down
Output load >90%
Output load >50%
Min. Typ. Max. Units
90
264 Vac
47
55
63
Hz
78.5
70.5
86.5
78
Vac
15 Arms
90
Apk
95%
75%
OUTPUT VOLTAGE CHARACTERISTICS
Output
Voltage
Parameter
Conditions
48V
3.3Vsb
5Vsb
12Vsb
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Output Current
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Operating Range
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Operating Range
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Operating Range
Load Capacitance
20MHz Bandwidth
Min. Typ. Max. Units
46.54
48
49.44
Vdc
480 mV p-p
2
24.6
A
10000 μF
3.3
3.2
3.4
Vdc
50 mV p-p
0
4.5
A
1530
μF
4.85
5
5.15
Vdc
50 mV p-p
0
4
A
1530
μF
11.2
12
12.4
Vdc
120 mV p-p
0
1.7
A
1530
μF
1 Ripple and noise are measured with 0.1 uF of ceramic capacitance and 10 uF of tantalum capacitance on each of
the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short coaxial
cable with 50ohm scope termination is used.
Technical enquiries email: toronto@murata-ps.com, tel: +1 (866) 740 1232
C1U-W-1200-48-Tx.A04 Page 1 of 4