C1U-W-1200-12-TA1C Datasheet, PDF (1/4 Pages) Murata Power Solutions Inc. – AC/DC Front End Power Supply | |||
|
C1U-W-1200-12-Tx Series
AC/DC Front End Power Supply
PRODUCT OVERVIEW
The C1U-W-1200 is a 1200 Watt universal AC input, power-factor-corrected (PFC) front-end power supply for general
applications. The main output is 12V and standby output of either 5V or 3.3V. Packaged in U low proï¬le, it is designed
to deliver reliable bulk power to servers, workstations, storage systems or any 12V distributed power architecture
systems requiring high power density. The highly efï¬cient electrical and thermal design with internal cooling fans sup-
ports reliable operation conditions. The C1U-W-1200 is designed to auto-recover from over-temperature faults.
FEATURES
RoHS compliant
1200W (110/220Vac) Output power
12V Main output,
3.3V or 5V standby output
Dimensions: 1.67â x 5.5â x 14.2â
9.2 Watts per cubic inch density
N+1 redundancy capable,
Active current sharing on main output
Over-voltage, over-current,
over-temperature protection
Internal cooling fans
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
SELECTION GUIDE
Part Number
C1U-W-1200-12-TA1C
C1U-W-1200-12-TC1C
C1U-W-1200-12-TA2C
C1U-W-1200-12-TC2C
Power Output
Universal Line
1200W
1200W
1200W
1200W
Main Output
12V
12V
12V
12V
Standby
Output
5V
3.3V
5V
3.3V
Airï¬ow
Front to back
Front to back
Back to front
Back to front
INPUT CHARACTERISTICS
Parameter
Input Voltage Operating Range
Input Frequency
Turn-on Input Voltage
Turn-off Input Voltage
Maximum Input Current
Inrush Current
Power Factor
Conditions
Ramp up
Ramp down
Output load >90%
Output load >50%
Min. Typ. Max. Units
90
264 Vac
47
55
63
Hz
78.5
70.5
86.5
78
Vac
15 Arms
90
Apk
95%
75%
OUTPUT VOLTAGE CHARACTERISTICS
Output
Voltage
Parameter
Conditions
12V
3.3Vsb
5Vsb
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Output Current
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Operating Range
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Operating Range
Load Capacitance
20MHz Bandwidth
Min.
11.75
0
3.2
0
4.85
0
Typ.
12.12
3.3
5
Max.
12.48
120
98.3
40000
3.4
33
6
1530
5.15
50
4
1530
Units
Vdc
mV p-p
A
μF
Vdc
mV p-p
A
μF
Vdc
mV p-p
A
μF
1 Ripple and noise are measured with 0.1 uF of ceramic capacitance and 2 x 270 uF of OSCON capacitance on each
of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short coaxial
cable with 50ohm scope termination is used. See Ripple Test Setup diagram.