MTU16V2000DS1100 Datasheet, PDF (3/7 Pages) MTU Onsite Energy Corporation – DIESEL GENERATOR SET | |||
|
◁ |
3 / // â/ MTU 16V2000 DS1100 / 3E / 50 Hz / 380V - 415V
Application dataâ
//â Cooling/Radiator System
Coolant flow rate (HT circuit):
m3/h
Heat rejection to coolant:
kW
Heat rejection to charge air:
kW
Heat radiated to ambient:
kW
Fan power for mech. radiator (40°C):
kWm
Fan power for mech. radiator (50°C):
kWm
Air flow required for mech. radiator (40°C) cooled unit:
m3/min
Air flow required for mech. radiator (50°C) cooled unit:
m3/min
Engine coolant capacity (without cooling equipment):
l
Radiator coolant capacity (40°C):
l
Radiator coolant capacity (50°C):
l
Max. coolant temperature (warning):
°C
Max. coolant temperature (shutdown):
°C
Fuel consumption optimized Emission optimizedâ
41.6
41.6
370
350
145
205
40
40
43.4
43.4
43.4
43.4
1462
1462
1462
1462
70
70
83
83
104
104
102
102
105
105
//â Exhaust System
Exhaust gas temp. (after turbocharger):
°C 530
515
Exhaust gas volume:
m3/s
2.78
3.07
Maximum allowable back pressure:
mbar 50
50
Minimum allowable back pressure:
mbar 30
30
//â Generator
Protection class IP2x
IP2x
Insulation class H H
Voltage regulation (steady state) ± 0.25%
± 0.25%
Rado interference class N
N
â All data refers only to the engine and is based on ISO standard conditions (25°C and 100m above sea level).