DS1100D5S Datasheet, PDF (3/4 Pages) MTU Onsite Energy Corporation – DIESEL GENERATOR SET AIR CHARGE-AIR COOLING
3 / // / 50 Hz 1100 kVA
STANDARD FEATURES➀
// The engine-generator set complies to G3
// Engine generator set tested according to ISO 8528-5 for
transient response
// Accepts rated load in one step as per NFPA 110
// All engine-generator sets are type and factory tested
// MTU Onsite Energy is a single source supplier
// Global product support
// Cooling System (integral set-mounted; engine driven fan)
// 16V2000 diesel engine (31,84 Liter (1943 cu inch)
displacement; 4-stroke)
// Engine-generator resiliently mounted
// Complete range of accessories
// Brushless, rotating field generator (PMG excitation;
250% short circuit capability; 2/3 pitch stator windings)
// Complete system metering
// LCD display
APPLICATION DATA
// Engine
Manufacturer
Model
Type
Arrangement
Displacement: L (cu inch)
Bore: mm (inch)
Stroke: mm (inch)
Compression ratio
Rated speed rpm
Engine Governor
Max power: kWm (bhp)
Speed regulation
Air filter
// Lube Oil Capacity
MTU
16V2000G65TD
4-Stroke
16-V
1.99 (121)
130 (5.1)
150 (5.9)
16:1
1500
Electronic isochronous
975 (1307)
±0.25%
Dry
// Fuel Consumption➁
At 100% of power rating:
At 75% of power rating:
At 50% of power rating:
gal/hr
62
45
31
// Cooling/Radiator System
Ambient capacity of radiator: °C
Max. restriction of cooling air, intake,
and discharge side of rad.: kPa (in. H 0)
2
Water pump capacity: l/min (gpm)
Heat rejection to coolant: kW (BTUM)
Heat rejection to after cooler: kW (BTUM)
Heat radiated to ambient: kW (BTUM)
Engine coolant capacity: l (gal)
Coolant to cooler temperature: °C (°F)
Total oil system: l (gal)
102 (27) // Air Requirements➃
// Electrical
Electric Volts DC
Cold cranking amps under -17.8 °C (0 °F)
24
1000
// Fuel System
Fuel supply connection size
Fuel return connection size
Maximum fuel lift: m (ft)
Recommended fuel
Total fuel flow: l/hr (gal/hr)
M22x1,5 - 60°/Male
M12x1,5 - 60°/Male
5 (16)
see MTU fluids & lubrication spec.
600 (159)
Aspirating: m3/min (SCFM)
Air flow required for rad.
cooled unit: m3/min
// Exhaust System
Gas temp. (stack): °C (°F)
Gas volume flow
temp: m3/min (SCFM)
Maximum allowable
back pressure: kPA
l/hr
g/kwh
234
199
172
195
116
198
40 (optional 50)➂
0,2 (0,803)
667 (176)
420 (23,885)
200 (11,374)
45 (2559)
110 (29)
95 (203)
72 (2540)
1236 (43606)
535 (995)
198 (6985)
8,5 (34)
➀ Represents standard product only.Consult Factory/MTU Onsite Energy distributor for additional configurations.
➁ Values in accordance with ISO 3046-1. Conversion calculated with fuel density of 0.83 g/ml.
➂ System ratings at 50°C may differ.
➃ Air density = 1.184 kg/m3 (0.0739 lbm/ft3)