English
Language : 

40-GC6NLT1_14 Datasheet, PDF (3/4 Pages) MTU Onsite Energy Corporation – GAS GENERATOR SET
3 / //  / 40-GC6NLT1
APPLICATION DATA
//  Engine
Manufacturer
Model
Type
Arrangement
Displacement: L (in3)
Bore: cm (in)
Stroke: cm (in)
Compression Ratio
Rated RPM
Engine Governor
Maximum Power (NG): kWm (bhp)
Maximum Power (LP): kWm (bhp)
Speed Regulation
Air Cleaner
//  Liquid Capacity (Lubrication)
Total Oil System: L (gal)
Engine Jacket Water Capacity: L (gal)
System Coolant Capacity: L (gal)
//  Electrical
Electric Volts DC
Cold Cranking Amps Under -17.8 °C (0 °F)
//  Fuel Inlet
Fuel Supply Connection Size
Fuel Supply Pressure: mm H20 (in. H20)
//  Fuel Consumption (NG-1000 BTU/ft3 / LP-2500 BTU/ft3)
GM
4.3L
4-Cycle
6-V
4.3 (262)
10.2 (4)
8.8 (3.5)
9.4:1
1,800
Bosch
49.6 (66.5)
53.2 (71.4)
C/F
Dry
At 100% of Power Rating: m3/hr (ft3/hr)
At 75% of Power Rating: m3/hr (ft3/hr)
At 50% of Power Rating: m3/hr (ft3/hr)
NG
13.9 (489)
10.4 (368)
7.3 (256)
//  Cooling - Radiator System
Ambient Capacity of Radiator: °C (°F)
50 (122)
Maximum Restriction of Cooling Air, Intake,
and Discharge Side of Rad.: kPa (in. H20)
Water Pump Capacity: L/min (gpm)
0.12 (0.5)
117.3 (31)
Heat Rejection to Coolant: kW (BTUM) 39 (2,220)
Heat Radiated to Ambient: kW (BTUM) 16.5 (938)
Fan Power: kW (hp)
3.4 (4.5)
LPG
6.1 (216)
4.6 (163)
3.2 (113)
3.4 (4.5)
4.2 (1.1)
7.2 (1.9)
21.6 (5.7)
12
925
//  Air Requirements
Aspirating: *m3/min (SCFM)
Air Flow Required for Rad.
Cooled Unit: *m3/min (SCFM)
Remote Cooled Applications;
Air Flow Required for Dissipation
of Radiated Gen-set Heat For a
Max of 25 °F Rise: *m3/min (SCFM)
3.9 (136.5)
211.4 (7,464)
59.9 (2,114)
* Air density = 1.184 kg/m3 (0.0739 lbm/ft3)
3/4” NPT
178–279 (7–11)
//  Exhaust System
Gas Temp. (Stack): °C (°F)
Gas Volume at Stack
Temp: m3/min (CFM)
Maximum Allowable
Back Pressure: kPa (in. H20)
704.4 (1,300)
12.5 (440.8)
10 (40)