English
Language : 

100-JS6DT3 Datasheet, PDF (3/4 Pages) MTU Onsite Energy Corporation – Diesel Engine-Generator sET
3 / //  / 100-JS6DT3
Application data
//  Engine
Manufacturer
Model
Type
Arrangement
Displacement: Cu In (lit)
Bore: in (cm)
Stroke: in (cm)
Compression Ratio
Rated RPM
Engine Governor
Max Power: Standby: bhp (kWm)
Regulation
Frequency
Air Cleaner
//  Liquid Capacity (Lubrication)
Total Oil System: gal (lit)
Engine Jacket Water Capacity: gal (lit)
System Coolant Capacity: gal (lit)
//  Electrical
Electric Volts DC
Cold Cranking Amps Under 0°F (-17.8°C)
//  Fuel System
Fuel Supply Connection Size
Fuel Return Connection Size
Maximum Fuel Lift: ft (m)
Recommended Fuel
Total Fuel Flow: gal/hr (lit/hr)
John Deere
4045HF285
4-Cycle
4-Inline
275 (4.5)
4.19 (10.6)
8 (12.7)
19:1
1,800
JDEC
158 (118)
±1%
60 Hz
Dry
3.2 (12)
3.3 (12.5)
5.3 (20.1)
12
800
3/8” NPT
3/8” NPT
10 (3)
Diesel #2
19.7 (74.6)
//  Fuel Consumption
At 100% of Power Rating: gal/hr (lit/hr)
At 75% of Power Rating: gal/hr( lit/hr)
At 50% of Power Rating: gal/hr (lit/hr)
8.2 (31)
6.6 (25)
4.7 (17.8)
//  Cooling - Radiator System
Ambient Capacity of Radiator: °F (°C)
Max. Restriction of Cooling Air, Intake,
and Discharge Side of Rad.: in. H20 (kPa)
Water Pump Capacity: gpm (lit/min)
Heat Rejection to Coolant: BTUM (kW)
Heat Rejection to Air to Air: BTUM (kW)
Heat Radiated to Ambient: BTUM (kW)
122 (50)
0.5 (0.12)
48 (180)
3,544 (62)
1,127 (19.8)
726 (13)
//  Air Requirements
Aspirating: *SCFM (m3/min)
Air Flow Required for Rad.
Cooled Unit: *SCFM (m3/min)
Air Flow Required for Heat
Exchanger/Remote Rad. based
on 25°F Rise: *SCFM (m3/min)
* Air density = 0.0739 lbm/ft3 (1.184 kg/m3)
288 (8.2)
6,635 (188)
1,638 (47)
//  Exhaust System
Gas Temp. (Stack): °F (°C)
Gas Volume at Stack
Temp: CFM (m3/min)
Maximum Allowable
Back Pressure: in. H20 (kPa)
1,076 (580)
805 (22.8)
30 (7.5)