TF0111 Datasheet, PDF (1/1 Pages) MTRONPTI – Varactor Tunable Preselector Filter
TF0111 Varactor Tunable Preselector Filter
118MHz – 137MHz – typical performance
I. General & Electrical Requirements
1. Tuned Center Frequency Range:
FMIN = 118MHz to FMAX = 137MHz
2. Passband @ 3dB: FSIG ±600kHz
3. Passband Insertion Loss: ≤ 3.5dB
4. Input/Output VSWR (within the FSIG Bandwidth into 50): < 1.50:1
5. Absolute Stop Band Attenuation:
FSIG ±10%: 15dB minimum
FSIG ±20%: 25dB minimum
6. In-Band IIP3: +30dBm minimum
7. In Band RF Power Handling: ≤ +20dBm (Peak, No Damage)
8. ZIN/ZOUT: 50 nominal
9. Tuning Method:
Voltage Control (VTUNE): +1.0VDC to +10.0VDC
II. Environmental & Physical Requirements
1. Temperature Range:
Operating: -40°C to +85°C
Storage: -45°C to +90°C
2. Solderability: Per EIAJ-STD-002
3. Package:
Size: 1.25” (L) x 0.5” (W) x 0.350” (Max., H)
Type: SMD (See Figure 1)
Reflow Profile: See Figure 2
Tape & Reel: 100-unit minimum
Figure 1: TF0111 Outline & PAD Layout Drawing
Figure 2: Reflow Profile
III. Data Sheet Revision:
Date
Rev. Author
9/11/13
B
MFE
07/09/13 A
06/28/13
-
BRM
BRM
Details of Revision
Adjusted the Stop Band, VSWR, and voltage range specification points and added a Max. notation for package
height..
Updated the Figure 1 drawing to include a suggested PAD Layout.
Original Draft.