English
Language : 

MSK5250-120 Datasheet, PDF (2/5 Pages) M.S. Kennedy Corporation – Hermetic Surface Mount Package
ABSOLUTE MAXIMUM RATINGS 10
VINP
VIN
VEN
IOUT
Input Voltage (100mS 1%D.C.) -20V to +60V
Input Voltage 26V ○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Enable Voltage ○
○
○
○
○
○
○
○
○
○
-0.3V to 26V
Output Current 5.0A ○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
TST Storage Temperature Range . . -65°C to +150°C
TLD Lead Temperature . . . . . . . . . . . . . . . . . 3 0 0 ° C
(10 Seconds Soldering)
TJ Operating Temperature
MSK 5250 Series . . . . . . . . . -40°C to +85°C
MSK 5250H Series . . . . . . . -55°C to +125°C
ELECTRICAL SPECIFICATIONS
Parameter
Test Conditions 1 3
Output Voltage Tolerance
IOUT = 10mA; VIN = VOUT +1V
Dropout Voltage 2
ΔVOUT = -1%; IOUT = 250 mA
ΔVOUT = -1%; IOUT = 5A
Load Regulation 8
VIN = VOUT+1.5V
10 mA ≤ IOUT ≤ 4.5A
Line Regulation
(VOUT +1V) ≤ VIN ≤ 26V
IOUT = 10 mA
Output Current Limit 2 9 VOUT = 0V; VIN = VOUT +1V
Ground Current 2
VIN = VOUT +1V; IOUT = 2.5A
VIN = VOUT +1V; IOUT = 5A
Output Noise 2
CL = 20μF; 10 HZ ≤ f ≤ 100 KHZ
Thermal Resistance 2
Junction to Case @ 125°C
Thermal Shutdown 2
TJ
Group A MSK 5250H SERIES
MSK 5250 SERIES
Subgroup Min.
Typ.
Max. Min.
Typ.
Max. Units
1
-
±0.5 ±1.0
-
±0.5 ±1.0 %
2, 3
-
±1.0 ±2.0
-
-
-
%
1
-
125 250
-
125 275 mV
1
-
370 600
-
370 625 mV
1
-
±0.2 ±1.0
-
±0.2 ±1.2 %
2, 3
-
±0.3 ±2.0
-
±0.3
-
%
1
- ±0.05 ±0.5
- ±0.05 ±0.6 %
2, 3
-
±0.5 ±1.0
-
±0.5
-
%
-
-
7.5
10
-
7.5
10
A
-
-
25
60
-
25
65
mA
-
-
80
-
-
80
-
mA
-
-
400
-
-
400
-
μV
-
-
1.7
2.0
-
1.7
2.2 °C/W
-
-
130
-
-
130
-
°C
NOTES:
PART
NUMBER
MSK5250-1.5
MSK5250-1.7
OUTPUT
VOLTAGE
7
+1.5V
+1.7V
1 Output decoupled to ground using 47μF minimum capacitor unless otherwise specified.
MSK5250-1.9
+1.9V
2 This parameter is guaranteed by design but need not be tested.
Typical parameters are representative of actual device performance but are for reference only.
MSK5250-2.5
+2.5V
3 All output parameters are tested using a low duty cycle pulse to maintain TJ = TC.
MSK5250-3.3
+3.3V
4 Industrial grade devices shall be tested to subgroup 1 unless otherwise specified.
5 Military grade devices ('H' suffix) shall be 100% tested to subgroups 1,2,3.
MSK5250-5.0
+5.0V
6 Subgroup 1 TC = +25°C
Subgroup 2 TJ = +125°C
MSK5250-12
+12.0V
Subgroup 3 TA = -55°C
7 Please consult the factory if alternate output voltages are required.
8 Due to current limit, maximum output current may not be available at all values of VIN-VOUT and temperatures.
See typical performance curves for clarification.
9 The output current limit function provides protection from transient overloads but it may exceed the maximum continuousrating.
Continuous operation in current limit may damage the device.
10 Continuous operation at or above absolute maximum ratings may adversely effect the device performance and/or life cycle.
2