English
Language : 

MSK5230-25 Datasheet, PDF (2/6 Pages) M.S. Kennedy Corporation – Hermetic Surface Mount Package
ABSOLUTE MAXIMUM RATINGS 10
VINP Input Voltage (100mS 1%D.C.)
VIN Input Voltage
VEN Enable Voltage
IOUT Output Current
-20V to +60V
26V
-0.3V to 26V
3.0A
TST Storage Temperature Range
TLD Lead Temperature
(10 Seconds Soldering)
TJ Operating Temperature
MSK5230 Series
MSK5230H Series
ESD Rating
-65°C to +150°C
300°C
-40°C to +85°C
-55°C to +125°C
Class 2
ELECTRICAL SPECIFICATIONS
Parameter
Test Conditions 1 3
Output Voltage Tolerance
IOUT = 10mA; VIN = VOUT +1V
Dropout Voltage 2
Load Regulation 8
∆VOUT = -1%; IOUT = 100 mA
∆VOUT = -1%; IOUT = 3A
10 mA ≤ IOUT ≤ 2.5A
Line Regulation
Output Current Limit 2 9
Ground Current 2 8
Output Noise 2
Thermal Resistance 2
Thermal Shutdown 2
(VOUT +1V) ≤ VIN ≤ 26V
IOUT = 10 mA
VOUT = 0V; VIN = VOUT +1V
VIN = VOUT +1V; IOUT = 1.5A
VIN = VOUT +1V; IOUT = 3A
CL = 20µF; 10 HZ ≤ f ≤ 100 KHZ
Junction to Case @ 125°C
TJ
Group A
Subgroup
1
2, 3
1
1
1
2, 3
1
2, 3
-
-
-
-
-
-
MSK5230H SERIES
Min. Typ.
Max.
-
±0.5
±1.0
-
±1.0
±2.0
-
80
200
-
350
600
-
±0.2
±1.0
-
±0.3
±2.0
-
±0.05 ±0.5
-
±0.5
±1.0
-
4.5
5.0
-
20
45
-
42
-
-
400
-
-
3.3
3.7
-
130
-
MSK5230 SERIES
Min. Typ. Max.
-
±0.5 ±1.0
-
-
-
-
80
225
-
350
625
-
±0.2 ±1.2
-
±0.3
-
-
±0.05 ±0.6
-
±0.5
-
-
4.5
5.0
-
20
45
-
42
-
-
400
-
-
3.3
3.9
-
130
-
Units
%
%
mV
mV
%
%
%
%
A
mA
mA
µV
°C/W
°C
NUMBER
MSK5230-1.5
MSK5230-1.7
MSK5230-1.8
NOTES:
MSK5230-1.9
1 Output decoupled to ground using 47µF minimum capacitor unless otherwise specified.
MSK5230-2.5
2 This parameter is guaranteed by design but need not be tested.
Typical parameters are representative of actual device performance but are for reference only.
3 All output parameters are tested using a low duty cycle pulse to maintain TJ = TC.
MSK5230-3.3
MSK5230-5.0
4 Industrial grade devices shall be tested to subgroup 1 unless otherwise specified.
5 Military grade devices ('H' suffix) shall be 100% tested to subgroups 1,2,3.
6 Subgroup 1 TC = +25°C
Subgroup 2 TJ = +125°C
Subgroup 3 TA = -55°C
MSK5230-12
7 Please consult the factory if alternate output voltages are required.
8 Due to current limit, maximum output current may not be available at all values of VIN-VOUT and temperatures.
See typical performance curves for clarification.
9 The output current limit function provides protection from transient overloads but it may exceed the maximum continuous rating.
Continuous operation in current limit may damage the device.
10 Continuous operation at or above absolute maximum ratings may adversely effect the device performance and/or life cycle.
AGE
7
+1.5V
+1.7V
+1.8V
+1.9V
+2.5V
+3.3V
+5.0V
+12.0V
2