ABSOLUTE MAXIMUM RATINGS
7
+VIN
-VIN
PD
+IOUT
-IOUT
TJ
+Input Voltage (VIN-VOUT)
+40VDC
○
○
○
○
○
○
○
-Input Voltage (VIN-VOUT) ○ ○ ○ ○ ○ ○ ○ ○ -40VDC
Power Dissipation ○ ○ ○ ○ ○ ○ ○ Internally Limited
+Output Current
1.5A
○
○
○
○
○
○
○
○
○
○
○
○
○
○
-Output Current 1.5A ○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Junction Temperature ○ ○ ○ ○ ○ ○ ○ ○ ○ +150°C
TST
Storage Temperature Range ○
○
○
-65°C to +150°C
○
TLD Lead Temperature Range ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 300°C
(10 Seconds)
TC Case Operating Temperature
MSK 5211-5214 ○
○
○
○
○
○
○
○
○
-40°C to +85°C
○
MSK 5211-5214H ○ ○ ○ ○ ○ ○ ○ ○ -55°C to +125°C
ELECTRICAL SPECIFICATIONS
Parameter
Test Conditions
POSITIVE OUTPUT REGULATORS:
Output Voltage Tolerance
IOUT=10mA; VIN=VOUT+3V
Dropout Voltage
IOUT=0.5A; ΔVOUT=1%
Load Regulation
10mA≤IOUT≤0.5A
VIN=VOUT+3V
Line Regulation
IOUT=10mA
VOUT+3V≤VIN≤35V
Thermal Resistance 1
JUNCTION TO CASE @ 125°C
NEGATIVE OUTPUT REGULATORS:
Output Voltage Tolerance
IOUT=10mA; VIN=VOUT -3V
Dropout Voltage
IOUT=0.5A; ΔVOUT=1%
Load Regulation
Line Regulation
Thermal Resistance 1
10mA≤IOUT≤0.5A
VIN=VOUT -3V
IOUT=10mA
-35V≤VIN≤VOUT-3V
JUNCTION TO CASE @ 125°C
Group A
MSK 521X H
Subgroup
3
4
Min. Typ. Max.
MSK 521X
2
Units
Min. Typ. Max.
1
- ±0.2 ±1.0
- ±0.2 ±1.5 %
2,3
- ±0.8 ±3.0
-
-
-
%
1
-
1.6 3.0
-
1.6 3.5 V
2,3
-
1.9 3.0
-
-
-
V
1
- ±0.2 ±2.0
- ±0.2 ±2.5 %
2,3
- ±0.4 ±2.5
-
-
-
%
1
- ±0.6 ±1.5
- ±0.6 ±2.0 %
2,3
- ±1.0 ±2.5
-
-
-
%
-
-
12.5 13.5
-
12.5 14.0 °C/W
1
- ±0.2 ±1.0
- ±0.2 ±1.5 %
2,3
- ±0.8 ±3.0
-
-
-
%
1
-
1.9 3.0
-
1.9 3.0 V
2,3
-
1.5 3.0
-
-
-
V
1
- ±0.2 ±2.0
- ±0.2 ±2.5 %
2,3
- ±0.4 ±2.5
-
-
-
%
1
- ±0.1 ±1.5
- ±0.1 ±2.0 %
2,3
- ±0.2 ±2.5
-
-
-
%
-
-
13.5 14.5
-
13.5 15.0 °C/W
NOTES:
1 Guaranteed by design but not tested. Typical parameters are representative of actual device
performance but are for reference only.
2 Industrial devices shall be tested to subgroup 1 unless otherwise specified.
3 Military grade devices shall be 100% tested to subgroups 1,2 and 3.
4 Subgroup 1 TA=TC=+25°C
Subgroup 2 TA=TC=+125°C
Subgroup 3 TA=TC=-55°C
5 Please consult the factory if alternate output voltages are required.
6 For positive regulator, output decoupled to ground using 1μF minimum tantalum capacitor unless
otherwise specified. For negative regulator, output decoupled to ground using 1μF minimum
tantanlum capacitor.
7 Continuous operation at or above absolute maximum ratings may adversly effect the device
performance and/or life cycle.
2
PART 5
NUMBER
MSK5211
MSK5212
MSK5213
MSK5214
OUTPUT VOLTAGES
POSITIVE NEGATIVE
5.0
5.0
10.0
10.0
12.0
12.0
15.0
15.0
8548-76 Rev. B 10/12