English
Language : 

MSK5116-17_15 Datasheet, PDF (2/5 Pages) M.S. Kennedy Corporation – Electrically Isolated Top Tab or Z Tab SIP
ABSOLUTE MAXIMUM RATINGS 9
VINP
VIN
VEN
IOUT
Input Voltage (100mS 1%D.C.) -20V to +60V
Input Voltage 26V ○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Enable Voltage ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ -0.3V to 26V
Output Current
3.5A
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
TST Storage Temperature Range -65°C to +150°C
TLD Lead Temperature ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 300°C
(10 Seconds Soldering)
TJ Operating Temperature
MSK 5116 Series ○ ○ ○ ○ ○ ○ ○ -40°C to +85°C
MSK 5116H Series ○ ○ ○ ○ ○ ○ -55°C to +125°C
ELECTRICAL SPECIFICATIONS
Parameter
Output Voltage Tolerance
Dropout Voltage 2
Load Regulation 8
Line Regulation
Output Current Limit 2
Ground Current 2
Output Noise 2
Enable Input Voltage 2
Enable Input Current 2
Shutdown Output Current 2
Thermal Resistance 2
Thermal Shutdown 2
Test Conditions 1 3
Group A MSK 5116H SERIES
Subgroup Min. Typ. Max.
1
- ±0.5 ±1.0
IOUT=10mA; VIN=VOUT+1V
2,3
- ±1.0 ±2.0
ΔVOUT=-1%; IOUT=100m A
1
-
80 200
ΔVOUT=-1%; IOUT=1.5A
1
-
350 600
VIN=VOUT+5V
1
- ±0.2 ±1.0
10mA ≤ IOUT ≤ 1.25A
2,3
- ±0.3 ±2.0
(VOUT +1V) ≤ VIN ≤ 26V
1
- ±0.05 ±0.5
IOUT=10mA
2,3
- ±0.5 ±1.0
VOUT=0V; VIN=VOUT+1V
-
-
2.1 3.5
VIN=VOUT+1V; IOUT=0.75A
-
-
18
30
VIN=VOUT+1V; IOUT=1.5A
-
-
32
-
CL=10μF; 10Hz ≤ f ≤ 100KHz
-
-
400
-
HIGH/ON
1
2.4 1.2
-
LOW/OFF 1
-
1.2 0.8
HIGH/ON
1
-
100 600
LOW/OFF 1
-
-
2
VENABLE ≤ 0.8V
-
-
10 500
Junction to Case @ 125°C
-
-
3.1 3.6
TJ
-
-
130
-
MSK 5116 SERIES
Min. Typ. Max.
- ±0.5 ±1.0
-
-
-
-
80 225
-
350 625
- ±0.2 ±1.2
- ±0.3 -
- ±0.05 ±0.6
- ±0.5 -
-
2.1 3.5
-
18
30
-
32
-
-
400
-
2.4 1.2
-
-
1.2 0.8
-
20 600
-
-
2
-
10 500
-
3.1 3.7
-
130
-
Units
%
%
mV
mV
%
%
%
%
A
mA
mA
μV
V
V
μA
μA
μA
°C/W
°C
NOTES:
1 Output decoupled to ground using 33μF minimum capacitance unless otherwise specified.
2 This parameter is guaranteed by design but need not be tested.
Typical parameters are representative of actual device performance but are for reference only.
3 All output parameters are tested using a low duty cycle pulse to maintain TJ = TC.
4 Industrial devices shall be tested to subgroup 1 unless otherwise specified.
5 Military grade devices ('B' suffix) shall be 100% tested to subgroups 1,2,3.
6 Subgroup 1 TC=+25°C
Subgroup 2 TJ=+125°C
Subgroup 3 TA=-55°C
7 Please consult the factory if alternate output voltages are required.
8 Due to current limit, maximum output current may not be available at all values of VIN-VOUT and
temperatures. See typical performance curves for clarification.
9 Continuous operation at or above absolute maximum ratings may adversely effect the device performance
and/or life cyle.
2