SPU65 SERIES
80W Desk Top Switching Power Supplies For I.T.E.
Description:
The SPU65 series of AC/DC switching mode power supplies
provide 80 Watts of continuous output power. All supplies are
UL 94V-1 min compliant, include IEC-320-C14 input for
worldwide applications. All models meet FCC Part-15 class B
and CISPR-22 class B emission Limits and are designed to
comply with UL/c-UL(UL 60950), TUV/GS(EN 60950) and new
CE requirements. All units are 100% burned in and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Single to Quad Output
Output Voltage Available From 3 VDC Thru 48 VDC
Optional Output Connector (See appendix)
Input Surge Current, Over Voltage and Over Load protection
Splash proof
Class I Insulation
Two Years Warranty
Safety Approvals :
CB
PS
E
S&E
Electrical Characteristics:
Product Safety
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin
Fin
Wo
Vo
Io
Iil
Iih
Irl
Irh
Eff
REG-i
REG-o
OVP
OCP
Ttr
Thold
Ts
Vrn
Ilk
Tc
Input Voltage
Input Frequency
Output Power Range
Output Voltage Range
Output Current Range
Input Current (Low Line)
Input Current (High Line)
Low Line Inrush Current
High Line Inrush Current
Efficiency
Line Regulation
Load Regulation
Over Voltage Protection
Over Current Protection
Transient Response
Hold-Up Time
Start Up Time
Ripple & Noise (Pe ak to Peak)
Safety Ground Leakage Curr ent
Temperature Coefficient
Operating Voltage
90
264
47
63
Vin=90 to 264VAC
0
80
See rating chart
See rating chart
Io=Full load, Vin=115VAC
1.9
Io=Full load, Vin=230VAC
1.5
Io=Full load, 25°c, Cool start,
Vin=115VAC
12 15
Io=Full load, 25°c, Cool start,
Vin=230VAC
26 30
Io=Full Load, Vin=230VAC
75 83 88
Io=Full Load
0.5 1
Vin=230VAC
37
112
132
110
150
Io=Full Load to Half Load, Vin=100VAC
4
Io=Full Load, Vin=110VAC
16
Io=Full Load, Vin=100VAC
0.3 1 2
Full Load, Vin=90VAC
12
Io=Full Load, Vin=240VAC
0.5 0.75
All output
-0.04
0.04
VAC
Hz
W
V
A
A
A
A
A
%
%
%
%
%
mS
mS
S
%
mA
%/°c
Environmental :
Sym.
Parameter
Toper Operating Temperature
Te s t Conditions
Tstg Storage Temperature
Hr Relative Humidity
Pd Derate linearly from 100% load at 40 C to 50% load at 70 C
Min. Typ. Max.
0
70
-40
85
5
95
Unit
C
C
%
Safety Specifications:
Sym.
Parameter
Vps
Dielectric Withstanding Voltage
for Primary to secondary
Dielectric Withstanding Voltage
Vpg for Primary to Ground
Ri Isolation Resistance
CISPR EMI requirements for CISPR-22
FCC EMI requirements for FCC PART-15
Te s t Conditions
Primary to secondary
Primary to ground
Test Voltage=500VDC
Vin=220VAC
Vin=110VAC
Min. Typ. Max. Unit
4242
VDC
2121
50
B
B
VDC
M
CLASS
CLASS