English
Language : 

SPU60 Datasheet, PDF (1/2 Pages) Astrodyne Corporation – 60W Desktop Switching Power Supplies
SPU60 SERIES
60W Desk Top Switching Power Supplies For I.T.E.
Description:
The SPU60 series of AC/DC switching mode power supplies
provide 60 Watts of continuous output power. All supplies are
UL 94V-1 min compliant. All models meet FCC Part-15 class B
and CISPR-22 class B emission Limits and are designed to
comply with UL/c-UL(UL 60950-1:2ndEdition), Intertek/GS(EN
60950-1:2ndEdition) and new CE requirements. All units are
100% burned in and tested.
Features:
Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Single output
Optional Output Connector (See appendix)
Over Voltage Protection (Crowbar Design)
Splash proof
Class I
2 year warranty
Safety Approvals :
CB
S&E
Electrical Characteristics:
Agree to apply for the PSE
if order on hand
Sym.
Para mete r
Test Conditions
Min. Typ. Max. Unit
Safety Approvals Input
Vin Voltage Range
10 0
240 VAC
Operate Voltage Range
90
264 VAC
fin Input Frequency
47
63 Hz
Po Output Power Range
Vin=90 to 264VAC
0
60
W
Vo Output Voltage Range
See rating chart V
Io Output Current Range
See rating chart A
Iil Input Current (Low Line)
Io=Full load, Vin=115VAC
1.6 A
Iih Input Current (High Line)
Irl Low Line Inrush Current
Irh High Line Inrush Current
Eff Efficiency
Io=Full load, Vin=230VAC
Io=Full load, 25c, Cool start,
Vi n=115V AC
Io=Full load, 25c, Cool start,
Vi n=230V AC
Io=Full Load, Vin=230VAC
1.0 A
40 43
A
80 85
A
75 87 90
%
REG-i Line Regulation
Io=Full Load
0.5 1
%
REG-o Load Regulation
Vi n=230V AC
37
%
OVP Over Voltage Protection
11 2
132 %
OCP Over Current Protection
11 0
150 %
Ttr Time of Transient Response Io=Full Load to Half Load, Vin=100VAC
4
mS
Thold Hold-Up Time
Io=Full Load, Vin=110VAC
16
mS
Ts Start Up Time
Io=Full Load, Vin=100VAC
0.3 1 2
S
* Vp-p Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
TC Temperature Coefficient
All output
0.5 1
0.5 0.75
-0. 04
0.04
%
mA
%/c
* Note: The Ripple & Noise which is under 3.3VDC at 2% max
Environmental :
Sym.
Parameter
Toper Operating Temperature
T e s t Conditions
Tstg Storage Temperature
Ho Operating Humidity
Hr Storage Humidity
MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Pd Derate linearly from 100% load at 40 C to 50% load at 70 C
Min. Typ. Max.
0 40 70
-40
85
0
95
0
75
0.1M
Unit
C
C
%
%
Hrs