English
Language : 

SPU46 Datasheet, PDF (1/2 Pages) MPS Industries, Inc. – SPU46 SERIES
SPU46 SERIES
50W Desk Top Switching Power Supplies For I.T.E.
Description:
The SPU46 series of AC/DC switching mode power supplies
provide 50 Watts of continuous output power. All supplies are
UL 94V-1 min compliant. All models meet FCC Part-15 class B
and CISPR-22 class B emission Limits and are designed to
comply with UL/c-UL(UL 60950-1:2ndEdition), TUV/GS(EN
60950-1:2ndEdition) and new CE requirements. All units are
100% burned in and tested.
Features:
Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Single Output
Optional Output Connector (See appendix)
Input Surge Current, Over Voltage And Over Load protection
Over Voltage Protection (Crowbar Design)
Energy Star 2.0, Efficiency level V
Class I
2 year warranty
Electrical Characteristics:
Sym.
Parameter
Safety Approvals :
CB
Agree to apply for the PSE
if order on hand
Test Conditions
Min. Typ. Max. Unit
Vin
fin
Po
Vo
Io
Iil
Iih
Irl
Irh
Eff
R EG-i
R EG-o
OVP
OCP
Ttr
T hold
Ts
Vp -p
Ilk
TC
Safety Approvals Input
Voltage Range
10 0
240 VAC
Operate Voltage Range
90
264 VAC
Input Frequency
Output Power Range
Vin=90 to 264VAC
47
63 Hz
0
50
W
Output Voltage Range
Output Current Range
See rating chart V
See rating chart A
Input Current (Low Line)
Input Current (High Line)
Low Line Inrush Current
High Line Inrush Current
Effi ciency
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
Io=Full load, 25c, Cool start,
Vin= 115VAC
Io=Full load, 25c, Cool start,
Vin= 230VAC
Io=Full Load, Vin=230VAC
1.1 A
0.55 A
12 23
A
26 45
A
83 85 88
%
Line Regulation
Io=Full Load
0.5 1
%
Load Regulation
Vi n=230V AC
3 15
%
Over Voltage Protection
11 2
132 %
Over Current Protection
11 0
150 %
Time of Transient Response Io=Full Load to Half Load, Vin=100VAC
4
mS
Hold-Up Time
Io=Full Load, Vin=110VAC
16
mS
Start Up Time
Io=Full Load, Vin=100VAC
0.3 1 2
S
Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
0.5 1
%
Safety Ground Leakage Current Io=Full Load, Vin=240VAC
0.5 0.75 mA
Temperature Coefficient
All output
-0. 04
0.04 %/c
Environmental :
Sym.
Parameter
T e s t Conditions
Toper Operating Temperature
Tstg Storage Temperature
Ho Operating Humidity
Hr Storage Humidity
MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Pd Derate linearly from 100% load at 40 C to 50% load at 70 C
Min. Typ. Max. Unit
0 40 70
C
-40
85
C
0
95 %
0
75 %
0.1M
Hrs