English
Language : 

SPU31 Datasheet, PDF (1/2 Pages) MPS Industries, Inc. – SPU31 SERIES
SPU31 SERIES
30W Desk Top Switching Power Supplies For I.T.E.
Description:
The SPU31 series of AC/DC switching mode power supplies
provide 30 Watts of continuous output power. All supplies are
UL 94V-1 min compliant, include IEC-320-C14 input for
worldwide applications. All models meet FCC Part-15 class B
and CISPR-22 class B emission Limits and are designed to
comply with UL/c-UL(UL 60950-1), TUV/GS (EN 60950-1) and
new CE requirements. All units are 100% burned in and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Single Output
Output Voltage Available From 5 VDC Thru 50 VDC
Optional Output Connector (See appendix)
Energy Star 2.0, Efficiency level V
Class I
2 year warranty
Safety Approvals:
CB
Electrical Characteristics:
Agree to apply for the PSE
if order on hand
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin Input Voltage
Operating Voltage
90
264 VAC
fin Input Frequency
47
63 Hz
Po Output Power Range
Vin=90 to 264VAC
0
30
W
Vo Output Voltage Range
Io Output Current Range
See rating chart V
See rating chart A
Iil Input Current (Low Line)
Io=Full load, Vin=115VAC
0.8 A
Iih Input Current (High Line)
Io=Full load, Vin=230VAC
0.5 A
Irl Low Line Inrush Current
Irh High Line Inrush Current
Eff Efficiency
Io=Full load, 25c, Cool start,
V in=115V AC
38 45
A
Io=Full load, 25c, Cool start,
V in=230V AC
26 30
A
Io=Full Load, Vin=230VAC
73 81 90
%
REG-i Line Regulation
Io=Full Load
0.5 1
%
REG-o Load Regulation
V in=230V AC
37
%
OCP Over Current Protection
11 0
150 %
Ttr Time of Transient Response Io=Full Load to Half Load, Vin=100VAC
4
mS
Thold Hold-Up Time
Io=Full Load, Vin=110VAC
12
mS
Ts Start Up Time
Io=Full Load, Vin=100VAC
0.3 1 2
S
Vrn Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
0.5 1
%
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
TC Temperature Coefficient
All output
Pno No-Load Power Consumption
No load, Vin=240VAC
0.5 0.75
-0.0 4
0. 04
0 0.3 0.5
mA
%/c
W
Environmental :
Sym.
Parameter
T e s t Conditions
Toper Operating Temperature
Tstg Storage Temperature
Hr Relative Humidity
MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Pd Derate linearly from 100% load at 40 C to 50% load at 70 C
Min. Typ. Max. Unit
0
-40
5
0.1M
70
C
85
C
95 %
Hrs