English
Language : 

SPU26 Datasheet, PDF (1/2 Pages) MPS Industries, Inc. – SPU26 SERIES
SPU26 SERIES
25W Interchangeable Wall Mount Switching Power Supplies For I.T.E.
Description:
The SPU26 series of AC/DC switching mode power
supplies provide 25 Watts of continuous output power. All
supplies are UL 94V-1 min compliant. All models meet FCC
Part-15 class B and CISPR-22 class B emission Limits and are
designed to comply with UL/c-UL(UL 60950-1:2ndEdition),
TUV/GS(EN 60950-1:2ndEdition) and new CE requirements. All
units are 100% burned in and tested.
Features:
Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz
Interchangeable Plug
Optional Output Connector (See appendix)
Single Output
Energy Star 2.0, Efficiency level V
Class II
2 year warranty
Electrical Characteristics:
Safety Approvals:
CB
PS Agree to apply for the PSE
E if order on hand
Sym.
Para mete r
Test Conditions
Min. Typ. Max. Unit
Safety Approvals Input
Vin Voltage Range
10 0
240 VAC
Operate Voltage Range
fin Input Frequency
90
264 VAC
47
63 Hz
Po Output Power Range
Vo Output Voltage Range
Vin=90 to 264VAC
25
W
See rating chart V
Io Output Current Range
See rating chart A
Iil Input Current (Low Line)
Iih Input Current (High Line)
Irl Low Line Inrush Current
Irh High Line Inrush Current
Eff Efficiency
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
Io=Full load, 25c, Cool start,
Vin =115V AC
Io=Full load, 25c, Cool start,
Vin =230V AC
Io=Full Load, Vin=230VAC
0.55 A
0.35 A
25 50
A
50 100 A
77 82 85
%
REG-i Line Regulation
Io=Full Load
0.5 1
%
REG-o Load Regulation
Vin =230V AC
35
%
OVP Over Voltage Protection
Ni l
%
OCP Over Current Protection
Nil.But,Output protected to short circut conditions %
Ttr Time of Transient Response Io=Full Load to Half Load, Vin=100VAC
4
mS
Thold Hold-Up Time
Io=Full Load, Vin=110VAC
12
mS
Ts Start Up Time
Io=Full Load, Vin=100VAC
23
S
Vp-p Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
0.5 1
%
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
0.25 mA
TC Temperature Coefficient
All output
-0. 04
0.04 %/c
Pno No-Load Power Consumption
No load, Vin=240VAC
0 0.25 0.3 W
Environmental :
Sym.
Parameter
T e s t Conditions
Toper Operating Temperature
Tstg Storage Temperature
Ho Operating Humidity
Hr Storage Humidity
MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Pd Derate linearly from 100% load at 40 C to 50% load at 70 C
Min. Typ. Max. Unit
0 40 70
C
-40
85
C
0
95 %
0
75 %
0.1M
Hrs