SPU130 SERIES
130W Desk Top (or Mounting Tab) Switching Power Supplies For I.T.E. ( PFC )
Description:
The SPU130 series of AC/DC switching mode power supplies
provide 130 Watts of continuous output power. All supplies are UL
94V-1 min compliant, include IEC-320-C14 input for worldwide
applications. All models meet FCC Part-15 class B and CISPR-22
class B emission Limits and are designed to comply with UL/c-
UL(UL 60950-1) , ITS/GS(EN 60950) and new CE requirements.
All units are 100% burned in and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Output Voltage Available From 3 VDC Thru 55 VDC
Optional Output Connector (See appendix)
Single and Dual Output
Input Surge Current, Over Voltage and Over Load protection
Power Factor Correction(PFC)
Option : Mounting Tab and Desk Top
Long Hold Up Times (75ms)
Safety Approvals :
Class I Insulation
Include a cooling fan
Two years warranty
Electrical Characteristics:
CB
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin Input Voltage
Operating Voltage
90
264 VAC
Fin Input Frequency
47
63 Hz
PFC Power Factor Correction
Io=Full load, Vin=230 VAC
0.95
0.99
Wo Output Power Range
Vo Output Voltage Range
Io Output Current Range
Vin=90 to 264VAC
0
130 W
See rating chart V
See rating chart A
Iil Input Current (Low Line)
Iih Input Current (High Line)
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
3.2 A
1.7 A
Irl Low Line Inrush Current
Irh High Line Inrush Current
Eff Efficiency
Io=Full load, 25°c ,Cool start,
Vin=115VAC
Io=Full load, 25°c, Cool start,
Vin=230VAC
Io=Full Load, Vin=230VAC
15 30
A
30 60
A
80 85
%
REG-i Line Regulation
Io=Full Load
0.5 1
%
REG-o Load Regulation
Vin=230VAC
37
%
OVP Over Voltage Protection
112
132 %
OCP Over Current Protection
110
150 %
Ttr Transient Response
Io=Full Load to Half Load, Vin=100VAC
4
mS
Thold Hold-Up Time
Io=Full Load, Vin=110VAC
75
mS
Ts Start Up Time
Io=Full Load, Vin=100VAC
0.3 1 2
S
Vrn Ripple & Noise (Pe ak to Peak) Full Load, Vin=90VAC
12
%
Ilk Safety Ground Leakage Curr ent Io=Full Load, Vin=240VAC
0.5 0.75 mA
Tc Temperature Coefficient
All output
-0.04
0.04 %/°c
Environmental :
Sym.
Parameter
Te s t Conditions
Min. Typ. Max. Unit
Toper Operating Temperature
0
Tstg Storage Temperature
-40
Hr Relative Humidity
5
Pd Derate linearly from 100% load at 40 C to 50% load at 70 C
70
C
85
C
95 %