English
Language : 

SBU58 Datasheet, PDF (1/2 Pages) MPS Industries, Inc. – SBU58 SERIES
SBU58 SERIES
60W Open frame Switching Power Supplies For I.T.E.
Description:
The SBU58 series of products,open frame constructed, AC/DC
switching mode power supplies provide 60 Watts of continuous
output power. They are suited for use in portable equipments
and many other applications. All models meet CISPR-22 class B
emission Limits and are designed to comply with new CE
requirements. All units are 100% burned in and tested.
Features:
Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz
Internal EMI filter
Input connector mates with Molex housing 35977-0300 and
Molex 35922 series crimp terminal
Single Output
Input Surge Current, Over Voltage and Over Load protection
Over Voltage Protection (Crowbar Design)
Class I
2 year warranty
Safety Approvals:
BAUART
GEPRUFT
TYPE
Product Safety APPROVED
CB
Electrical Characteristics:
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Safety Approvals Input
Vin Voltage Range
10 0
240 VAC
Operate Voltage Range
90
264 VAC
fin Input Frequency
47
63 Hz
Po Output Power Range
Vin=90 to 264VAC
0
60
W
Vo Output Voltage Range
See rating chart V
Io Output Current Range
See rating chart A
Iil Input Current (Low Line)
Io=Full load, Vin=115VAC
1.2 A
Iih Input Current (High Line)
Io=Full load, Vin=230VAC
0.6 A
Irl Low Line Inrush Current
Irh High Line Inrush Current
Eff Efficiency
Io=Full load, 25c, Cool start,
Vi n=115V AC
12 15
A
Io=Full load, 25c, Cool start,
Vi n=230V AC
26 30
A
Io=Full Load, Vin=230VAC
77 80 90
%
REG-i Line Regulation
Io=Full Load
0.5 1
%
REG-o Load Regulation
Vi n=230V AC
35
%
OVP Over Voltage Protection
11 2
132 %
OCP Over Current Protection
11 0
150 %
Ttr Time of Transient Response Io=Full Load to Half Load, Vin=100VAC
4
mS
Thold Hold-Up Time
Io=Full Load, Vin=110VAC
12
mS
Ts Start Up Time
Io=Full Load, Vin=100VAC
0.3 1 2
S
Vp-p Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
0.5 1
%
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
0.4 0.75 mA
TC Temperature Coefficient
All output
-0. 04
0.04 %/c
Pno No-Load Power Consumption
No load, Vin=240VAC
0. 1
0.5 W
Environmental :
Sym.
Parameter
T e s t Conditions
Toper Operating Temperature
Tstg Storage Temperature
Ho Operating Humidity
Hr Storage Humidity
MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Pd Derate linearly from 100% load at 40 C to 50% load at 70 C
Min. Typ. Max. Unit
0 40 70
C
-40
85
C
0
95 %
0
75 %
0.1M
Hrs