ELECTRICAL SPECIFICATION @ 25°C
PART NO
Turns
Pri OCL Pri DCR Insertion Loss Insertion Loss Insertion Loss
Ratio
(µH) Min (W) Max
dB Max
dB Max
dB Typ
R3600-
Pri : Sec ±5% 1-4
1-4
1MHz
100MHz
300MHz
1
1:1
500
0.30
-0.5
-1.0
-2.6
2
1CT:1CT
800
0.50
-0.5
-1.2
-3.5
3
1:2
120
0.20
-0.8
-1.0
-1.5
4
1:1:1
120
0.20
-0.8
-1.0
-1.5
5
3:3:1
200
0.30
-0.5
-1.0
-3.0
6
1:1.224
500
0.50
-0.8
-1.0
-3.0
Note:
• OCL measured @ 100KHz, 0.1VRMS at Pin 1-4 (with 2-3 shorted)
• Insertion Loss measured with 100W as Input (Primary) Impedance between 1-4 and Output (Secondary) load with respective impedance
• 50W and 75W impedance data available upon request
Hipot
VRMS
Pri to Sec
4500
3000
4500
4500
3000
3000
Schematic
B
A
B
C
C
B
Mechanical
Schematic
Schematic A
Schematic B
Dimensions
Unless otherwise specified, all tolerances are:
inch: .XX : ± 0.015 .XXX : ±0.004
mm: X,X : ± 0,38 X,XX : ±0,10
Schematic C
Product performance is limited to specified parameter. Data is subject to change without prior notice.
2570 W. 237th Street, Suite B
Torrance, CA 90505
Tel: (310) 325-1043
Fax: (310) 325-1044
R3600-XX
1004JW
www.mpsind.com
sales@mpsind.com