English
Language : 

PP25F Datasheet, PDF (1/2 Pages) MPS Industries, Inc. – PLANAR TRANSFORMERS HIGH FREQUENCY 140 WATT
PLANAR TRANSFORMERS
HIGH FREQUENCY 140 WATT
PP25F SERIES
• Power Rating Up to 140 Watts
• High Efficiency
• High Power Density of 600 Watts Per Cubic Inch
• Footprint 23.5 mm X 20.10 mm
• Lower Profile of 9.12 mm
• High Isolation (operational) 1500 Vdc
• High Frequency 200 KHz – 700 kHz
• Operating Temperature -40ºC to +125ºC
• Custom Design Available
ELECTRICAL PARAMETERS @25°C
Part Number
PP25F-
Primary
Inductance
(μH MIN)
0802
0902
1002
1102
1202
0803
0903
1003
1103
1203
0804
0904
1004
1104
1204
151.0
191.0
236.0
286.0
340.0
151.0
191.0
236.0
286.0
340.0
151.0
191.0
236.0
286.0
340.0
Leakage
Inductance
(μH MAX)
0.43
0.43
0.45
0.55
0.60
0.43
0.43
0.45
0.55
0.60
0.43
0.43
0.45
0.55
0.60
DC Resistance
(mΩ MAX)
Primary
A
Aux
Secondary
18.0
18.0
0.9 & 0.9
18.0
20.0
0.9 & 0.9
20.0
20.0
0.9 & 0.9
20.0
26.0
0.9 & 0.9
26.0
26.0
0.9 & 0.9
18.0
18.0
1.8 & 1.8
18.0
20.0
1.8 & 1.8
20.0
20.0
1.8 & 1.8
20.0
26.0
1.8 & 1.8
26.0
26.0
1.8 & 1.8
18.0
18.0
8.00
18.0
20.0
8.00
20.0
20.0
8.00
20.0
26.0
8.00
26.0
26.0
8.00
Turns Ratio
Primary
4T/4T
4T/5T
5T/5T
5T/6T
6T/6T
4T/4T
4T/5T
5T/5T
5T/6T
6T/6T
4T/4T
4T/5T
5T/5T
5T/6T
6T/6T
Secondary
1T & 1T
1T & 1T
1T & 1T
1T & 1T
1T & 1T
2T & 1T
2T & 1T
2T & 1T
2T & 1T
2T & 1T
4T
4T
4T
4T
4T
NOTES:
1. The Irated is either 85% of the Isaturation or the Iheating depending which is lower.
2. The Isaturation is the current which causes the inductance to drop by 15% of its nominal value.
3. The Iheating is the current which causes the temperature of the part to increase by approximately 45°C.
Isolation
(VDC)
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
Figure
A
A
A
A
A
B
B
B
B
B
C
C
C
C
C
Product performance is limited to specified parameters.Data is subject to change without prior notice.
Tel: 310-325-1043
Fax: 310-325-1044
www.mpsind.com
sales@mpsind.com