MB5000RW Datasheet, PDF (3/4 Pages) MicroPower Direct, LLC – MB5000RW SERIES
EMC Specifications
www.micropowerdirect.com
All units should meet EN 55022 (CE/RE) class A/B
with the simple external circuit shown; using the Standard
Model
C1
C2
L1
C3
C4
component values given in the table.
MB5012x-xxRW 22 µF/25V 1210 MLCC
---
---
---
---
To meet the requirements of EN 61000-4-4 and EN55022 Class A MB5024x-xxRW 3.3 µF/50V 1210 MLCC
---
---
---
---
EN 61000-4-5, the value of C1 should be changed
MB5048x-xxRW 2.2 µF/100V 1210 MLCC
---
---
---
---
to 330 µF/200V. Contact the factory for more EN55022 Class B MB50xxS-xxRW 3.3 µF/100V 1210/X7S 3.3 µF/100V 1210/X7S
1 mH
1,000 pF/2kV 1808 X7R 1,000 pF/2kV 1808 X7R
information.
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT, See Notes
Surge, See Notes
CS
Standard
EN 55022
Class A/B
EN 55022
Class A/B
EN 61000-4-2 Criteria B; ±8 kV Air, ±6 kV Contact
EN 61000-4-3
Criteria A; 10V/m
EN 61000-4-4
Criteria A; ±2 kV
EN 61000-4-5
Criteria A; ±1 kV
EN 61000-4-6
Criteria A; 10 V/m
Derating Curves
MB50xxS-03RW Without Heatsink
MB50xxS-03RW With Heatsink
MB5024/48S-05RW, -12RW, -15RW Without Heatsink
MB5024/48S-05RW, -12RW, -15RW With Heatsink
MB5012S-12RW, 15RW & MB50xxS-24RW Without Heatsink
MB5012S-12RW, 15RW & MB50xxS-24RW With Heatsink
MB5012S-05RW Without Heatsink
MB5012S-05RW With Heatsink
MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com