Model Selection Guide
Model
Number
MPM-20S-03
MPM-20S-05
MPM-20S-09
MPM-20S-12
MPM-20S-15
MPM-20S-24
Input
Current (A)
115 VAC 230 VAC
0.33 0.18
0.33 0.18
0.33 0.18
0.33 0.18
0.33 0.18
0.33 0.18
Voltage
(VDC)
3.3
5.0
9.0
12.0
15.0
24.0
Output
Current (A)
Max
Min
4.10
0.0
3.50
0.0
2.10
0.0
1.60
0.0
1.30
0.0
0.85
0.0
www.micropowerdirect.com
Over Volt.
Protection
(VDC)
7.5
7.5
12.0
20.0
20.0
30.0
Efficiency
(%, Typ)
73
75
77
81
83
85
Notes:
1. Operation at no load will not damage the units, however, they may not meet
all specifications.
2. Load regulation is measured for an output change of 10% to 100% at nominal
input line.
3. All units are rated for EN 55022 (CE/RE) class B without external components.
4. All units are rated for EN 61000-4-4 (±2 kV) without external components. They
will meet EN 61000-4-4 (±4 kV) with additional input filtering as shown below.
5. All units are rated for EN 61000-4-5 (±1 kV/±2 kV) without external components.
They will meet EN 61000-4-5 (±2 kV/±4 kV) with additional input filtering as shown
below.
6. It is recommended that a fuse be used on the input of a power supply for protection.
For the MPM-20S series, a 3.15A/250 VAC slow blow should be used.
Typical Connection
The diagram below illustrates a typical application connection of the MPM-20S-xx series. Notes on this circuit (starting with the input circuit) are:
1. It is recommended that an external fuse and NTC be used. The recommended
fuse is a 3.15A/250V slow blow and for the NTC, a 5D-9.
2. An external MOV is required on the input to protect the unit in the event of a surge.
A 561KD14 or equivalent is recommended.
3. A simple external circuit may be used to adjust the output ±10%. To adjust the
output DOWN, connect a 5%, 3W resistor between the plus output pin and the
VOUT trim pin. To adjust the output UP, connect a 5%, 3W resistor between the
minus output pin and the VOUT trim. Contact the factory for resistor values needed
to achieve a specific output.
4. Recommended output filtering capacitors are:
Typical Connection: With ACFM-01 Input Module (See note 5)
MPM-20S-03
MPM-20S-05
MPM-20S-09
MPM-20S-12
MPM-20S-15
MPM-20S-24
C1
330 µF/16V
330 µF/16V
220 µF/25V
220 µF/25V
220 µF/25V
220 µF/25V
C2
0.01 µF/25V
0.01 µF/25V
0.01 µF/25V
0.01 µF/25V
0.01 µF/25V
0.01 µF/25V
TVS
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
Derating Curve
Output capacitor (C2) is a high frequency, low resistance electrolytic capacitor.
Capacitor (C1) is ceramic. Voltage derating of capacitors should be 80% or above.
5. Input noise and surge suppression modules are available for a number of MPD
AC/DC power supplies. An MPM-20S-xx connection with the ACFM-01 is il-
lustrated in the diagram at left. For pricing or full technical information on these
modules (ACFM-01 and ACFM-02) please contact the factory.
Mechanical Dimensions
Pin Connections
Pin Function Pin
1 AC-Ground 4
2 AC-Neutral 8
3 AC-Line Trim
Function
-Vout
+Vout
Trim
Input Voltage Vs Load
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
We Power Your Success - For Less!
The MPM-20-xx series is also available with
a chassis mount or DIN mount adapter.
Contact the factory for more information
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com