English
Language : 

MA300MHI Datasheet, PDF (2/2 Pages) MicroPower Direct, LLC – MA300MHI SERIES
Model Selection Guide
www.micropowerdirect.com
Model
Number
Input
Voltage (VDC)
Current (mA)
Nominal Range Full-Load No-Load
MA305MS-05HI 5.0
4.5 - 5.5 1,000
130
MA305MS-12HI 5.0
4.5 - 5.5
960
130
MA305MS-15HI 5.0
4.5 - 5.5
960
130
MA305MD-12HI 5.0
4.5 - 5.5 1,000
130
MA305MD-15HI 5.0
4.5 - 5.5 1,000
130
MA312MS-05HI 12 10.8 - 13.2 420
60
MA312MS-12HI 12 10.8 - 13.2 400
60
MA312MS-15HI 12 10.8 - 13.2 400
60
MA312MD-12HI 12 10.8 - 13.2 420
60
MA312MD-15HI 12 10.8 - 13.2 420
60
MA324MS-05HI 24 21.6 - 26.4 210
40
MA324MS-12HI 24 21.6 - 26.4 195
40
MA324MS-15HI 24 21.6 - 26.4 195
40
MA324MD-12HI 24 21.6 - 26.4 210
40
MA324MD-15HI 24 21.6 - 26.4 210
40
Voltage
(VDC)
5.0
12.0
15.0
±12.0
±15.0
5.0
12.0
15.0
±12.0
±15.0
5.0
12.0
15.0
±12.0
±15.0
Output
Current
(mA, Max)
600
250
200
±125
±100
600
250
200
±125
±100
600
250
200
±125
±100
Current
(mA, Min)
0.0
0.0
0.0
±0.0
±0.0
0.0
0.0
0.0
±0.0
±0.0
0.0
0.0
0.0
±0.0
±0.0
Capacitive
Load
(µF, Max)
470
470
470
±220
±220
470
470
470
±220
±220
470
470
470
±220
±220
Efficiency
(%, Typ)
60
62
62
60
60
60
62
62
60
60
60
64
64
60
60
Fuse Rating
Slow-Blow
(mA)
2,000
2,000
2,000
2,000
2,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
Notes:
1. When measuring output ripple, it is recommended that an external 0.33 µF ceramic
capacitor be placed from the +VOUT pin to the -VOUT pin for single output units and from
each output to common for dual output units. For noise sensitive applications, the use
of 1.5 µF capacitors will reduce the output ripple.
2. Dual output units may be connected to provide a 24 VDC or 30 VDC output. To do this,
connect the load across the positive (+VOUT) and negative (-VOUT) outputs and float the
output common.
3. The converter should be connected to a low ac-impedance source. An input source with
a highly inductive impedance may affect the stability of the converter. In applications
where the converter output loading is high and input power is supplied over long lines,
it may be necessary to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0⍀ at 100 kHz) capacitor be
mounted close to the converter. For 5V input units a 4.7 µF is recommended, for 12V
and 24V units a 2.2 µF.
4. It is recommended that a fuse be used on the input of a power supply for protection.
See the table above for the correct rating.
Derating Curve
Mechanical Dimensions
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
Pin Connections
Pin Single
Dual
1
+VIN
+VIN
2
+VIN
+VIN
10
No Pin Common
11
No Pin Common
12
-VOUT
No Pin
13
+VOUT
-VOUT
15
No Pin
+VOUT
23
-VIN
-VIN
24
-VIN
-VIN
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com