English
Language : 

MA100RUI Datasheet, PDF (2/4 Pages) MicroPower Direct, LLC – MA100RUI SERIES
Model Selection Guide
www.micropowerdirect.com
Model
Number
Input
Output
Voltage (VDC)
Nominal Range
Current (mA)
Voltage Current
Full-Load No-Load (VDC) (mA, Max)
MA124S-05RUI-xx 24 9.0 - 36.0 91.0
20
5.0
300.0
MA124S-09RUI-xx 24 9.0 - 36.0 89.0
20
9.0
167.0
MA124S-12RUI-xx 24 9.0 - 36.0 86.0
20
12.0
125.0
MA124S-15RUI-xx 24 9.0 - 36.0 86.0
20
15.0
100.0
MA124S-24RUI-xx 24 9.0 - 36.0 88.0
30
24.0
62.5
MA124D-05RUI-xx 24 9.0 - 36.0 94.0
20
±5.0 ±150.0
MA124D-09RUI-xx 24 9.0 - 36.0 91.0
20
±9.0
±83.3
MA124D-12RUI-xx 24 9.0 - 36.0 89.0
20 ±12.0
±62.5
MA124D-15RUI-xx 24 9.0 - 36.0 89.0
20 ±15.0
±50.0
MA124D-24RUI-xx 24 9.0 - 36.0 90.0
30 ±24.0
±31.0
MA148S-05RUI-xx 48 18.0 - 72.0 44.0
10
5.0
300.0
MA148S-09RUI-xx 48 18.0 - 72.0 43.0
10
9.0
167.0
MA148S-12RUI-xx 48 18.0 - 72.0 42.0
10
12.0
125.0
MA148S-15RUI-xx 48 18.0 - 72.0 42.0
10
15.0
100.0
MA148S-24RUI-xx 48 18.0 - 72.0 43.0
10
24.0
62.5
MA148D-05RUI-xx 48 18.0 - 72.0 45.0
10
±5.0 ±150.0
MA148D-09RUI-xx 48 18.0 - 72.0 44.0
10
±9.0
±83.3
MA148D-12RUI-xx 48 18.0 - 72.0 43.0
10 ±12.0
±62.5
MA148D-15RUI-xx 48 18.0 - 72.0 43.0
10 ±15.0
±50.0
MA148D-24RUI-xx 48 18.0 - 72.0 44.0
10 ±24.0
±31.0
Current
(mA, Min)
100.0
55.7
41.7
33.3
20.8
±50.0
±27.8
±20.8
±16.7
±10.3
100.0
55.7
41.7
33.3
20.8
±50.0
±27.8
±20.8
±16.7
±10.3
Efficiency
(%, Typ)
Reflected
Ripple
Current
(mA Typ)
Capacitive
Load
(µF, Max)
Fuse
Rating
Slow-Blow
(mA)
68
35.0
2,200
200
70
35.0
470
200
72
35.0
470
200
72
35.0
470
200
71
35.0
220
200
66
35.0 ±1,000
200
68
35.0
±220
200
70
35.0
±220
200
70
35.0
±220
200
69
35.0
±100
200
70
35.0
2,200
100
72
35.0
470
100
74
35.0
470
100
74
35.0
470
100
72
35.0
220
100
68
35.0 ±1,000
100
70
35.0
±220
100
72
35.0
±220
100
72
35.0
±220
100
71
35.0
±100
100
For the alternate pin-out (see page 4) , add suffix “P2” to model number
(i.e. MA124S-05RUI-P2)
Notes:
1. Cross regulation is measured with the output being tested at 100% load while
the other output is varied from 25% to 100% load.
2. See the typical connection circuit on page three for typical external filtering components.
For help with a specific model or layout issue, contact the factory.
3. Isolation voltage is specified for Input to output. On units with the optional metal case,
the isolation voltage for Input - Case and Output - Case is 1,000 VDC.
4. Operation at no-load will not damage the unit, but they may not meet all specifications.
To meet all specifications, a minimum load of 33% should be maintained.
5. It is recommended that a fuse be used on the input of a power supply for protection.
See the Model Selection table above for the correct rating.
Model Number
NEW DIP DC/DC Converter
Families From MPD
Series
MA100X-xxRW
MA100X-xxRWI
MA100X-xxRU
MA100X-xxRUI
MA200X-xxRW
MA200X-xxRWI
MA200X-xxRU
MA200X-xxRUI
MA300X-xxRW
MA300X-xxRWI
MA300X-xxRU
MA300X-xxRUI
MA400X-xxRW
MA400X-xxRWI
MA400X-xxRU
MA400X-xxRUI
MA500X-xxRW
MA500X-xxRWI
MA500X-xxRU
MA500X-xxRUI
MA600X-xxRW
MA600X-xxRWI
MA600X-xxRU
MA600X-xxRUI
Power
1W
1W
1W
1W
2W
2W
2W
2W
3W
3W
3W
3W
4W
4W
4W
4W
5W
5W
5W
5W
6W
6W
6W
6W
Input Range
2:1
2:1
4:1
4:1
2:1
2:1
4:1
4:1
2:1
2:1
4:1
4:1
2:1
2:1
4:1
4:1
2:1
2:1
4:1
4:1
2:1
2:1
4:1
4:1
Isolation
1.5 kVDC
3.5 kVDC
1.5 kVDC
3.5 kVDC
1.5 kVDC
3.5 kVDC
1.5 kVDC
3.5 kVDC
1.5 kVDC
3.0 kVDC
1.5 kVDC
3.0 kVDC
1.5 kVDC
3.5 kVDC
1.5 kVDC
3.5 kVDC
1.5 kVDC
3.5 kVDC
1.5 kVDC
3.5 kVDC
1.5 kVDC
3.0 kVDC
1.5 kVDC
3.0 kVDC
Visit our website or contact the factory for more information.
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com