English
Language : 

I2000RW Datasheet, PDF (2/2 Pages) MicroPower Direct, LLC – Ultra-Miniature 20W Wide 2:1 Input Range DC/DC Converters
Model Selection Guide
www.micropowerdirect.com
Model
Number
I2001RW
I2002RW
I2003RW
I2004RW
I2011RW
I2012RW
I2013RW
I2014RW
I2021RW
I2022RW
I2023RW
I2024RW
Input
Output
Voltage (VDC)
Current (mA)
Voltage Current
Nominal Range Full-Load No-Load (VDC) (mA, Max)
12
9.0 - 18.0 1,961
90
3.3
4,500
12
9.0 - 18.0 1,873
90
5.0
4,000
12
9.0 - 18.0 1,873
50
12.0
1,660
12
9.0 - 18.0 1,873
50
15.0
1,330
24 18.0 - 36.0 986
45
3.3
4,500
24 18.0 - 36.0 936
45
5.0
4,000
24 18.0 - 36.0 936
25
12.0
1,660
24 18.0 - 36.0 936
25
15.0
1,330
48 36.0 - 75.0 496
28
3.3
4,500
48 36.0 - 75.0 473
28
5.0
4,000
48 36.0 - 75.0 473
15
12.0
1,660
48 36.0 - 75.0 473
15
15.0
1,330
Over
Current
(mA, Min)
Voltage
Protection
(VDC)
Efficiency
(%, Typ)
450
4.6
85
400
6.2
89
166
15.5
88
133
18.6
88
450
4.6
86
400
6.2
89
166
15.5
89
133
18.6
89
450
4.6
84
400
6.2
88
166
15.5
88
133
18.6
88
Capacitive
Load
(µF Max)
2,000
2,000
470
330
2,000
2,000
470
330
2,000
2,000
470
330
Fuse Rating
Slow-Blow
(mA)
4,000
4,000
4,000
4,000
2,000
2,000
2,000
2,000
1,000
1,000
1,000
1,000
Notes:
1. When measuring output ripple, it is recommended that an external ceramic capacitor
(approx 0.1 µF) be placed from the +Vout pin to the -Vout pin.
2. Unit recovers automatically from an over power condition once the fault is removed.
3. It is recommended that the units not be operated with a load under 10% of full
load. Operation at no-load will not damage the unit, but they may not meet all
specifications.
4. The On/Off Control input
Min
Max
(Pin 3) is referenced to -Vin On
5.0 VDC 15.0 VDC
(Pin 1). If it is not used, the Off
0.0 VDC 0.3 VDC
control pin should be left In. Current (on)
open.
In. Current (off)
5. It is recommended that a
-1 mA
1 mA
fuse be used on the input of a power supply for protection. See the Model Selection
table above for the correct rating.
Derating Curve
Pin Connections
Pin Function
1
+Vin
2
-Vin
3 Control (Optional)
4
+Vout
5
No Pin
6
-Vout
Mechanical Dimensions
MicroPower Direct
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” on the top of the unit
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com