Model Selection Guide
www.micropowerdirect.com
Model
Number
Input
Voltage (VDC)
Current (mA)
Voltage
Nominal Range Full-Load No-Load (VDC)
Output
Current
(mA, Max)
Current
(mA, Min)
Efficiency
(%, Typ)
Capacitive Fuse Rating
Load Slow-Blow
(µF Max)
(mA)
I1001RU
24
9.0 - 36.0 352
30
3.3
2,200
330
86
I1002RU
24
9.0 - 36.0 496
30
5.0
2,000
300
84
I1003RU
24
9.0 - 36.0 483
30
12.0
830
125
86
I1004RU
24
9.0 - 36.0 474
30
15.0
660
100
87
I1005RU
24
9.0 - 36.0 496
30
±5.0 ±1,000
±150
84
I1006RU
24
9.0 - 36.0 477
30
±12.0
±410
±61
86
I1007RU
24
9.0 - 36.0 474
30
±15.0
±330
±50
87
I1011RU
48 18.0 - 75.0 180
20
3.3
2,200
330
85
I1012RU
48 18.0 - 75.0 248
20
5.0
2,000
300
84
I1013RU
48 18.0 - 75.0 241
20
12.0
830
125
86
I1014RU
48 18.0 - 75.0 237
20
15.0
660
100
87
I1015RU
48 18.0 - 75.0 248
20
±5.0 ±1,000
±150
84
I1016RU
48 18.0 - 75.0 238
20
±12.0
±410
±61
86
I1017RU
48 18.0 - 75.0 237
20
±15.0
±330
±50
87
560
560
150
150
±220
±100
±100
560
560
150
150
±220
±100
±100
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
500
500
Notes:
1. Output ripple is measured with a 0.47 µF ceramic capcitor connected across the outputs.
2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
3. Operation at no-load will not damage the unit, but they may not
meet all specifications.
4. The On/Off Control input (Pin 3) is referenced to -Vin (Pin 2). If it is On
Min
2.5 VDC
not used, the control pin should be left open. If the pin is shorted to Off
0.0 VDC
-VIN, the unit will turn off.
In. Current (on)
6. It is recommended that a fuse be used on the input of a power
supply for
In. Current (off)
protection. See the Model Selection table above for the correct rating.
Max
50 VDC
1.0 VDC
0.5 mA
-0.5 mA
Pin Connections
Pin Single Dual
1 +Vin
+Vin
2 -Vin
-Vin
3 Remote ON/OFF
Pin Single
4 +Vout
5 No Pin
6 -Vout
Mechanical Dimensions
Dual
+Vout
Common
-Vout
Derating Curve - Without HeatSink
Derating Curve - With HeatSink
Mechanical Dimensions - With HeatSink
MicroPower Direct
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com