English
Language : 

G100EI_14 Datasheet, PDF (2/2 Pages) MicroPower Direct, LLC – G100EI SERIES
Model Selection Guide
Model
Number
G101EI
G102EI
G103EI
G104EI
G105EI
G106EI
G107EI
G108EI
G111EI
G112EI
G113EI
G114EI
G115EI
G116EI
G117EI
G118EI
G121EI
G122EI
G123EI
G124EI
G125EI
G126EI
G127EI
G128EI
Input
Voltage (VDC)
Current (mA)
Nominal Range Full-Load No-Load
5
4.5 - 5.5
286
30
5
4.5 - 5.5
267
30
5
4.5 - 5.5
256
30
5
4.5 - 5.5
250
30
5
4.5 - 5.5
278
30
5
4.5 - 5.5
267
30
5
4.5 - 5.5
256
30
5
4.5 - 5.5
253
30
12 10.8 - 13.2 115
15
12 10.8 - 13.2 110
15
12 10.8 - 13.2 105
15
12 10.8 - 13.2 103
15
12 10.8 - 13.2 113
15
12 10.8 - 13.2 110
15
12 10.8 - 13.2 105
15
12 10.8 - 13.2 104
15
24 21.6 - 26.4 57
8
24 21.6 - 26.4 54
8
24 21.6 - 26.4 52
8
24 21.6 - 26.4 51
8
24 21.6 - 26.4 56
8
24 21.6 - 26.4 55
8
24 21.6 - 26.4 52
8
24 21.6 - 26.4 51
8
Voltage
(VDC)
5.0
9.0
12.0
15.0
±5.0
±9.0
±12.0
±15.0
5.0
9.0
12.0
15.0
±5.0
±9.0
±12.0
±15.0
5.0
9.0
12.0
15.0
±5.0
±9.0
±12.0
±15.0
Output
Current
(mA, Max)
200.0
111.0
83.0
67.0
±100.0
±56.0
±42.0
±33.0
200.0
111.0
83.0
67.0
±100.0
±56.0
±42.0
±33.0
200.0
111.0
83.0
67.0
±100.0
±56.0
±42.0
±33.0
Current
(mA, Min)
20.0
12.0
9.0
7.0
±10.0
±6.0
±5.0
±4.0
20.0
12.0
9.0
7.0
±10.0
±6.0
±5.0
±4.0
20.0
12.0
9.0
7.0
±10.0
±6.0
±5.0
±4.0
Load
Regulation
(%, Max)
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
Other input/output combinations are available
(i.e 3.3 VDC). Contact the factory for details at:
sales@micropowerdirect.com
Derating Curve
Efficiency
(%, Typ)
70
75
78
80
72
75
78
79
72
76
79
81
74
76
79
80
73
77
80
82
74
76
80
81
Fuse Rating
Slow-Blow
(mA)
500
500
500
500
500
500
500
500
200
200
200
200
200
200
200
200
100
100
100
100
100
100
100
100
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.
2. These units should not be operated with a load under 10% of full load.
Operation at no-load may cause damage to the unit.
3. These converters will operate without external components. However,
when measuring output ripple, it is recommended that an external ceramic
capacitor be placed
from the +Vout pin to
the -Vout pin for single
Vin
Input
Capacitor
Vout
Output Capacitor
Single Dual
output units and from
each output to common
for dual output units.
An input capacitor will
enhance stability over
5 VDC
12 VDC
24 VDC
4.7 μF
2.2 μF
1.0 μF
5 VDC
9 VDC
12 VDC
15 VDC
10.0 μF
4.7 μF
2.2 μF
1.0 μF
4.7 μF
2.2 μF
1.0 μF
0.47 μF
temperature and input line variations. Recommended capacitor values are
given in the table above. For applications requiring very low output noise
levels, a simple LC filter should be effective.
4. Dual output units may be connected to provide a 10V, 18V, 24V or 30 VDC
output. To do this, connect the load across the positive (+Vout) and negative
(-Vout) outputs and float the output common
5. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Pin Connections
Pin Single Dual Pin
1 -Vin -Vin
9
7 NC NC
10
8 +Vout +Vout 14
NC= No Connection
Single
No Pin
-Vout
+Vin
Dual
Common
-Vout
+Vin
Mechanical Dimensions
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the side of the unit
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com