English
Language : 

E200I Datasheet, PDF (2/2 Pages) MicroPower Direct, LLC – High Isolation, 2W Ultra-Miniature, SIP DC/DC Converters
Model Selection Guide
Model
Number
Input
Output
Load
Voltage (VDC)
Current (mA) Voltage Current Current Regulation
Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (% Max)
E201I
5
4.5 - 5.5
372
38
3.3
400.0
40.0
12
E202I
5
4.5 - 5.5
533
38
5.0
400.0
40.0
12
E203I
5
4.5 - 5.5
500
38
9.0
222.0
22.0
8
E204I
5
4.5 - 5.5
500
38
12.0
167.0
16.0
8
E205I
5
4.5 - 5.5
500
38
15.0
133.0
13.0
8
E211I
12 10.8 - 13.2 150
30
3.3
400.0
40.0
8
E212I
12 10.8 - 13.2 200
30
5.0
400.0
40.0
8
E213I
12 10.8 - 13.2 211
30
9.0
222.0
22.0
8
E214I
12 10.8 - 13.2 199
25
12.0
167.0
16.0
8
E215I
12 10.8 - 13.2 208
25
15.0
133.0
13.0
8
E222I
24 21.6 - 26.4 107
12
5.0
400.0
40.0
8
E223I
24 21.6 - 26.4 102
12
9.0
222.0
22.0
8
E224I
24 21.6 - 26.4 104
12
12.0
167.0
16.0
8
E225I
24 21.6 - 26.4 102
12
15.0
133.0
13.0
8
E232I
48 44.0 - 52.0 53
6
5.0
400.0
40.0
8
E233I
48 44.0 - 52.0 52
6
9.0
222.0
22.0
8
E234I
48 44.0 - 52.0 53
6
12.0
167.0
16.0
8
E235I
48 44.0 - 52.0 52
6
15.0
133.0
13.0
8
Notes:
1. Output load regulation is specified for a load change of 20% to 100%.
2. When measuring output ripple, it is recommended that an external 0.33
µF ceramic capacitor be placed from the +Vout pin to the -Vout pin.
3. Operation at no-load will not damage these units. However, they may
not meet all specifications.
4. The 5V, 12V and 24V input units do not require external components to
operate, but the use of a low ESR capacitor (approximately 10 µF, ESR
<1.0Ω at 100 kHz) mounted close to the converter input pins is recom-
mended.
For 48 VDC input units, an input capacitor should always be used. Depen-
dent upon the application, a value between 4.7 µF and 47 µF should be
sufficient.
5. Out put capacitive load capability of these units is 33 µF max. Exceeding
this may cause start up problems.
5. It is recommended that a fuse be used on the input of a power supply
for protection. See the table above for the correct rating.
Derating Curve
Efficiency
(%, Typ)
71
75
79
80
80
73
77
79
84
80
78
82
80
82
78
80
78
80
Fuse Rating
Slow-Blow
(mA)
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
200
200
200
200
100
100
100
100
Pin Connections
Pin Description
1
-Vin
2
+Vin
3
-Vout
4
+Vout
Mechanical Dimensions
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation
on the side of the unit
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com