E200I Datasheet, PDF (2/2 Pages) MicroPower Direct, LLC – High Isolation, 2W Ultra-Miniature, SIP DC/DC Converters | |||
|
◁ |
Model Selection Guide
Model
Number
Input
Output
Load
Voltage (VDC)
Current (mA) Voltage Current Current Regulation
Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (% Max)
E201I
5
4.5 - 5.5
372
38
3.3
400.0
40.0
12
E202I
5
4.5 - 5.5
533
38
5.0
400.0
40.0
12
E203I
5
4.5 - 5.5
500
38
9.0
222.0
22.0
8
E204I
5
4.5 - 5.5
500
38
12.0
167.0
16.0
8
E205I
5
4.5 - 5.5
500
38
15.0
133.0
13.0
8
E211I
12 10.8 - 13.2 150
30
3.3
400.0
40.0
8
E212I
12 10.8 - 13.2 200
30
5.0
400.0
40.0
8
E213I
12 10.8 - 13.2 211
30
9.0
222.0
22.0
8
E214I
12 10.8 - 13.2 199
25
12.0
167.0
16.0
8
E215I
12 10.8 - 13.2 208
25
15.0
133.0
13.0
8
E222I
24 21.6 - 26.4 107
12
5.0
400.0
40.0
8
E223I
24 21.6 - 26.4 102
12
9.0
222.0
22.0
8
E224I
24 21.6 - 26.4 104
12
12.0
167.0
16.0
8
E225I
24 21.6 - 26.4 102
12
15.0
133.0
13.0
8
E232I
48 44.0 - 52.0 53
6
5.0
400.0
40.0
8
E233I
48 44.0 - 52.0 52
6
9.0
222.0
22.0
8
E234I
48 44.0 - 52.0 53
6
12.0
167.0
16.0
8
E235I
48 44.0 - 52.0 52
6
15.0
133.0
13.0
8
Notes:
1. Output load regulation is speciï¬ed for a load change of 20% to 100%.
2. When measuring output ripple, it is recommended that an external 0.33
µF ceramic capacitor be placed from the +Vout pin to the -Vout pin.
3. Operation at no-load will not damage these units. However, they may
not meet all speciï¬cations.
4. The 5V, 12V and 24V input units do not require external components to
operate, but the use of a low ESR capacitor (approximately 10 µF, ESR
<1.0Ω at 100 kHz) mounted close to the converter input pins is recom-
mended.
For 48 VDC input units, an input capacitor should always be used. Depen-
dent upon the application, a value between 4.7 µF and 47 µF should be
sufï¬cient.
5. Out put capacitive load capability of these units is 33 µF max. Exceeding
this may cause start up problems.
5. It is recommended that a fuse be used on the input of a power supply
for protection. See the table above for the correct rating.
Derating Curve
Efï¬ciency
(%, Typ)
71
75
79
80
80
73
77
79
84
80
78
82
80
82
78
80
78
80
Fuse Rating
Slow-Blow
(mA)
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
200
200
200
200
100
100
100
100
Pin Connections
Pin Description
1
-Vin
2
+Vin
3
-Vout
4
+Vout
Mechanical Dimensions
Notes:
⢠All dimensions are typical in inches (mm)
⢠Tolerance x.xx = ±0.01 (±0.25)
⢠Pin 1 is marked by a âdotâ or indentation
on the side of the unit
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072 ⢠TEL: (781) 344-8226 ⢠FAX: (781) 344-8481 ⢠E-Mail: sales@micropowerdirect.com
|