Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 16A Output Current
Input
Parameter
• Wide 6V - 14V Input Range Input Voltage Range
Conditions
VOUT Ϲ 4.5V
VOUT м 5.0V
Min.
6.0
6.5
Typ.
12.0
12.0
Max.
14.0
14.0
Units
VDC
• Efficiency to 94%
Turn On Voltage Threshold
5.0
• EN 60950 Approved (UL) Under Voltage Lockout, Power Up
Turn Off Voltage Threshold
4.0
VDC
• Miniature SMT Construction
• Short Circuit Protected
Maximum Input Current
Off Input Current
• Thermal Shutdown
Input Filter
Lockout Hysteresis Voltage
1.0
IOUT = 100%, VIn = 0 to 14 VDC
15.0
A
Input Idle Current
10
mA
Capacitive
• Remote On/Off Control
Input Reflected Ripple Current
See Note 1
200
mA P-P
• Sequencing Capability
Output
• Industry Standard Footprint Parameter
Output Voltage/Current
Conditions
Min. Typ. Max.
See Model Selection Guide
Units
Output Voltage Tolerance
±1.5
%
Line Regulation
VIN = Min to Max
±0.2
%
Load Regulation
IOUT = 0% to 100%
±0.5
%
Ripple & Noise (20 MHz)
See Note 2
75 mV P-P
30 mV RMS
Transient Recovery Time, See Note 3
50% Load Change
200
µSec
Temperature Coefficient
±0.03 %/°C
Power Good Signal (Optional)
Logic High 90
110
%VOUT
Short Circuit Protection
Continuous (Hiccup Mode)
Over Temperature Protection
See Note 4
130
°C
Overload Protection
See Note 5 19.2 25 32
A
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
Not Isolated
Switching Frequency
Fixed
300
kHz
Sequencing
Parameter
Conditions
Min. Typ. Max. Units
Sequencing Delay Time
10
mSec
Sequencing Slew Rate
dVSEQ/dt 0.1
1.0 V/mSec
Tracking
Power Up
Power Down
200
400
mV
Remote On/Off, See Note 6
Parameter
Conditions
Min. Typ. Max. Units
Unit On
Logic High
Open or VIN
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Unit Off
On/Off Current
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Logic Low 0.0
0.4
VON/VOFF = 0.0V
1
Conditions
Min. Typ. Max.
Ambient -40 +25 +85
-55
+125
VDC
mA
Units
°C
°C
T: (781) 344-8226
Cooling
Free Air Convection (See Derating Curves)
F: (781) 344-8481
Humidity
RH, Non-condensing
93
%
E: sales@micropowerdirect.com Physical
W: www.micropowerdirect.com Size
1.3 x 0.53 x 0.346 Inches (33.0 x 13.46 x 8.8 mm)
Weight
0.299 Oz (8.5g)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
980
kHours
Safety Standards
UL 60950, EN 60950
www.micropowerdirect.com