Electrical Specifications
Key Features:
• 10W Output Power
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
• 40 - 160 VDC Input Range Input Voltage Range
40.0 110.0 160.0 VDC
• Meets EN 60950, EN 50155 Input Start Voltage
40.0
VDC
• 1,500 VDC Isolation
• Efficiency to 86%
• Compact 1 x 2 Inch Case
• -40°C to +85°C Operation
Input Filter
Output
Parameter
Output Voltage Accuracy
Line Regulation
␲ (Pi) Filter
Conditions
Min.
VIN = Min to Max
Typ.
±1.0
±0.2
Max.
±2.0
±0.5
Units
%
%
• Industry Standard Pin-Out Load Regulation
IOUT = 10% to 100%
±0.5 ±1.0
%
• Chassis Mount Option
• DIN Rail Mount Option
Ripple (20 MHz)
Noise (20 MHz)
Transient Recovery Time, See Note 2
Transient Response Deviation
See Note 1
See Note 1
25% Load Step Change
15
30
60 100
500 1,000
±3.0 ±5.0
mV P - P
mV P - P
µS
%
Output Power Protection
110 120 140
%
Temperature Coefficient
±0.03
%/°C
Output Short Circuit, See Note 3
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
60 Seconds 1,500
VDC
Isolation Resistance
500 VDC 1,000
M
Isolation Capacitance
100 kHz/0.1V
1,000
pF
Switching Frequency
350
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +85
°C
Operating Temperature Range
Case
+105
°C
Storage Temperature Range
-55
+125
°C
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
See Mechanical Diagram (Page 2)
Case Material
Aluminum Alloy With Non-Conductive Base (UL94-V0)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Weight
Chassis Mount Adapter
DIN Rail Mount Adapter
Reliability Specifications
Parameter
Conditions
0.77 Oz (22g)
See Mechanical Diagram (Page 4)
See Mechanical Diagram (Page 4)
Min. Typ. Max. Units
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
MTBF
Vibration, 5 - 150 Hz
Absolute Maximum Ratings
MIL HDBK 217F, 25°C, Gnd Benign 1.0
Displacement Range
Acceleration
7.5 mm
2G
MHours
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Surge (1 Sec)
-0.7
200.0 VDC
Lead Temperature
1.5 mm From Case for 10 Sec
300
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.