English
Language : 

MPO-65S Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – Single Output, 65W Compact, Open Frame AC/DC Power Supplies
MPO-65S Series
Single Output, 65W
Compact, Open Frame
AC/DC Power Supplies
Key Features:
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• 65W Output Power
Parameter
Conditions
Min. Typ. Max. Units
• Universal 90-264 AC Input
• EN 60950 Compliant
• Low Leakage Current
Input Voltage Range
Input Frequency
Input Current
Universal 90
264
127
370
47
63
See Model Selection Guide
VAC
VDC
Hz
• Nine Single Output Models
• Meets EN55022
• >300 kHour MTBF
Inrush Current
Safety Ground Leakage Current
Cold Start, 115 VAC
20.0
Cold Start, 230 VAC
40.0
115 VAC
0.35
240 VAC
0.5
A Pk
mA
• Only 5” x 3” x 1.6”
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage
See Model Selection Guide
Output Current
See Model Selection Guide
Output Voltage Adjustment
See Model Selection Guide
Output Voltage Tolerance, See Note 1
See Model Selection Guide
Ripple & Noise (20 MHz), See Note 2
See Model Selection Guide
Hold-Up Time
115 VAC
15
230 VAC
60
mSec
Set-Up Time
230 VAC
800
mSec
Rise Time
230 VAC
20
mSec
RoHS Compliant Temperature Coefficient
Short Circuit Protection
±0.02
Continuous (Autorecovery)
%/°C
Over Voltage Protection
See Note 3 115
135
%
Overload Protection
See Note 4 112
160
%
General
Parameter
Conditions
Min. Typ. Max. Units
Input to Output 3,000
Isolation Voltage
Input to Ground 1,500
VAC
Output to Ground 500
Isolation resistance
500 VDC
100
MΩ
EMI/RFI
Conducted
EN 55022; EN 61000-3-2, -3
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
EMC Compliance
Switching Frequency
Environmental
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Fixed
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
65
kHz
T: (781) 344-8226
Parameter
F: (781) 344-8481
Operating Temperature Range
E: sales@micropowerdirect.com Storage Temperature Range
Conditions
Min. Typ. Max.
Ambient -10 +25 +60
-20
+85
Units
°C
°C
W: www.micropowerdirect.com Cooling
Free Air Convection (See Derating Curve)
Humidity
RH, Non-condensing
95
%
Physical
Size
5.00 x 3.00 x 1.65 Inches (127.0 x 76.2 x 42.0 mm)
Weight
7.4 Oz (0.21 kg)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 300
kHours
Safety Standards
IEN 60950, IEC 60950
Vibration
10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis