English
Language : 

MPO-40S Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – MPO-40S Series
MPO-40S Series
Single Output, 40W
Compact, Open Frame
AC/DC Power Supplies
Key Features:
• 40W Output Power
• Universal 90-264 AC Input
• EN 60950 Approved (UL)
• Compact 2 x 4 In Package
• Nine Standard Models
• Meets EN 55022 B
• Meets EN 61000-4
• >200 kHour MTBF
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Range
Universal 90
127
264
VAC
373
VDC
Input Frequency
47
63
Hz
Input Filter
Meets EN 55022 Class B; FCC Class B
Input Current
See Model Selection Guide
Inrush Current
Cold Start, 115 VAC
Cold Start, 230 VAC
32.0
A Pk
50.0
Safety Ground Leakage Current
264 VAC
3.5
mA
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage/Current
See Model Selection Guide
Output Voltage Tolerance
See Note 1
±1.0
%
Line Regulation
Vin = 100 VAC to 240 VAC
±0.5
%
Load Regulation
Iout = 10% to 100%
±1.0
%
Ripple & Noise (20 MHz)
See Note 2
±1.0
%
Hold-Up Time
115 VAC
8
230 VAC
100
mSec
Temperature Coefficient
±0.05
%/°C
Short Circuit Protection
Continuous (Autorecovery)
Overload Protection
See Note 3
150
%
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
Input to Output 3,000
VAC
Isolation Resistance
500 VDC
1,000
M⍀
Isolation Capacitance
4,700
pF
EMI/RFI
Conducted
EN 55022; EN 61000-3-2, -3
Electrostatic Discharge (ESD)
IEC/EN 61000-4-2, -6, -8, -11
EMC Compliance
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
IEC/EN 61000-4-3
IEC/EN 61000-4-4
Surge
IEC/EN 61000-4-5
Switching Frequency
Fixed
66
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient 0 +25 +50
°C
Storage Temperature Range
-20
+85
°C
Cooling
Free Air Convection (See Derating Curve)
Humidity
RH, Non-condensing
93
%
Physical
Size
4.00 x 2.00 x 1.20 Inches (101.60 x 50.08 x 30.48 mm)
Weight
5.99 Oz (0.170 kg)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 200
kHours
Safety Standards
UL 60950, EN 60950
Vibration
Sinusoidal 50~500 Hz, 3.0 Grms, Period of 30 min each along X, Y & Z Axis
www.micropowerdirect.com